Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis

Greenhouse design in tropical highlands must reconcile passive heat removal with the microclimatic requirements of horticultural crops. This study assessed how gutter height and roof opening area interact with external wind to influence ventilation, temperature, humidity, and atmospheric evaporative demand in a five-span greenhouse in the Bogotá Savanna, Colombia. A two-dimensional, steady-state computational fluid dynamics (CFD) model was used to simulate 60 combinations of gutter height (2–6 m), roof opening ratio (10–30% of floor area), and wind velocity (0–1.7 m s−1), considering roof-only ventilation and an uncropped interior. Response surface methodology (RSM) characterized the combined effects of the three factors. Area-normalized ventilation ranged from 0.026 to 0.163 m3 s−1 m−2, while mean air temperature ranged from 26.2 to 42.8 °C. Under windless conditions and a 30% opening ratio, increasing gutter height from 2 to 6 m reduced mean temperature from 35.3 to 28.9 °C. Across the warmest and coolest scenarios, estimated vapor pressure deficit decreased from 6.49 to 1.37 kPa. However, these scenarios shared a mean growing-zone air velocity of 0.3 m s−1, showing that greater air exchange did not necessarily increase local air movement. The quadratic models achieved adjusted R2 = 0.900–0.986; withholding complete height–opening combinations yielded RMSE values of 0.00596 m3 s−1 m−2 for ventilation, 0.895 °C for temperature, and 3.29 percentage points for relative humidity. Despite improved cooling, the lowest mean temperature exceeded the cited daytime ranges for rose, carnation, chrysanthemum, and alstroemeria. The findings identify greenhouse height and roof opening area as complementary design variables, while demonstrating that ventilation gains alone do not establish crop-specific climatic suitability under the evaluated conditions.

Authors

Institutions

Publication Details

Journal
Agronomy
Published
2026-11-19
DOI
https://doi.org/10.3390/agronomy16222339
Primary Topic
Greenhouse Technology and Climate Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis

Rodrigo Gil, Edwin Villagrán, Carlos Ricardo Bojacá, Jorge Flores-Velázquez et al.
Agronomy
Greenhouse Technology and Climate Control
article

Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis

Rodrigo Gil, Edwin Villagrán, Carlos Ricardo Bojacá, Jorge Flores-Velázquez, Cruz Ernesto Aguilar-Rodríguez
article en

Abstract

Greenhouse design in tropical highlands must reconcile passive heat removal with the microclimatic requirements of horticultural crops. This study assessed how gutter height and roof opening area interact with external wind to influence ventilation, temperature, humidity, and atmospheric evaporative demand in a five-span greenhouse in the Bogotá Savanna, Colombia. A two-dimensional, steady-state computational fluid dynamics (CFD) model was used to simulate 60 combinations of gutter height (2–6 m), roof opening ratio (10–30% of floor area), and wind velocity (0–1.7 m s−1), considering roof-only ventilation and an uncropped interior. Response surface methodology (RSM) characterized the combined effects of the three factors. Area-normalized ventilation ranged from 0.026 to 0.163 m3 s−1 m−2, while mean air temperature ranged from 26.2 to 42.8 °C. Under windless conditions and a 30% opening ratio, increasing gutter height from 2 to 6 m reduced mean temperature from 35.3 to 28.9 °C. Across the warmest and coolest scenarios, estimated vapor pressure deficit decreased from 6.49 to 1.37 kPa. However, these scenarios shared a mean growing-zone air velocity of 0.3 m s−1, showing that greater air exchange did not necessarily increase local air movement. The quadratic models achieved adjusted R2 = 0.900–0.986; withholding complete height–opening combinations yielded RMSE values of 0.00596 m3 s−1 m−2 for ventilation, 0.895 °C for temperature, and 3.29 percentage points for relative humidity. Despite improved cooling, the lowest mean temperature exceeded the cited daytime ranges for rose, carnation, chrysanthemum, and alstroemeria. The findings identify greenhouse height and roof opening area as complementary design variables, while demonstrating that ventilation gains alone do not establish crop-specific climatic suitability under the evaluated conditions.

AgronomyVol. 16(22)
Universidad Nacional de Colombia (CO), Tecnológico Nacional de México (MX), Colegio de Postgraduados (MX), Corporación Colombiana de Investigación Agropecuaria – AGROSAVIA (CO)
Greenhouse Technology and Climate Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon