WRF assessment of local climate zone dependent cooling effects of cool and green roofs during a Riyadh heatwave

Arid cities such as Riyadh, Saudi Arabia, face growing urban heat challenges due to the urban heat island effect and more intense heatwaves. Rapid urban development has increased the need for rooftop heat-mitigation strategies. However, limited studies have quantified the city-wide cooling performance of rooftop mitigation strategies across different local climate zones in arid environments. Using the Weather Research and Forecasting model coupled with the Building Effect Parameterization and Building Energy Model (WRF BEP + BEM) schemes and building height data, this study evaluated the cooling potential of green roofs with 50% (GR50) and 100% coverage (GR100) and cool roofs with albedo values of 0.84 (CR84) and 0.95 (CR95) across different LCZs for a heatwave in Riyadh. The GR50, GR100, CR84, and CR95 strategies reduced the average daytime surface temperature by 0.66 °C, 1.23 °C, 3.44 °C, and 4.62 °C, respectively, compared to the base case, which has an albedo of 0.20. The CR95 scenario also reduced the daytime surface urban heat island by up to 5.26 °C. The inter-LCZ assessment showed that CR95 reduced air temperature by up to 0.93 °C in compact low-rise areas (LCZ 3) and 0.98 °C in open high-rise areas (LCZ 4), demonstrating the potential of cool-roof retrofits to mitigate extreme heat in arid cities. Sensible heat flux was lower in the cool roof scenarios (70–130 W/m 2 ) than in the green roof scenarios (20–100 W/m 2 ), compared to the base case. Green roofs produced lower temperature reductions but increased latent heat flux and may provide additional co-benefits. Overall, this study provides a comparison of rooftop heat mitigation effectiveness during the selected heatwave, while broader planning applications require assessment across additional meteorological conditions and validation through real-world implementation.

Authors

Institutions

Publication Details

Journal
Frontiers in Environmental Science
Published
2026-11-19
DOI
https://doi.org/10.3389/fenvs.2026.1976329
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

WRF assessment of local climate zone dependent cooling effects of cool and green roofs during a Riyadh heatwave

Sami G. Al‐Ghamdi, Krishna Kishore Osuri, U.N. Athira, Buri Vinodhkumar et al.
Frontiers in Environmental Science
Urban Heat Island Mitigation
article

WRF assessment of local climate zone dependent cooling effects of cool and green roofs during a Riyadh heatwave

Sami G. Al‐Ghamdi, Krishna Kishore Osuri, U.N. Athira, Buri Vinodhkumar, Harsh Kamath, Furqan Tahir, Amjad Azmeer
article en

Abstract

Arid cities such as Riyadh, Saudi Arabia, face growing urban heat challenges due to the urban heat island effect and more intense heatwaves. Rapid urban development has increased the need for rooftop heat-mitigation strategies. However, limited studies have quantified the city-wide cooling performance of rooftop mitigation strategies across different local climate zones in arid environments. Using the Weather Research and Forecasting model coupled with the Building Effect Parameterization and Building Energy Model (WRF BEP + BEM) schemes and building height data, this study evaluated the cooling potential of green roofs with 50% (GR50) and 100% coverage (GR100) and cool roofs with albedo values of 0.84 (CR84) and 0.95 (CR95) across different LCZs for a heatwave in Riyadh. The GR50, GR100, CR84, and CR95 strategies reduced the average daytime surface temperature by 0.66 °C, 1.23 °C, 3.44 °C, and 4.62 °C, respectively, compared to the base case, which has an albedo of 0.20. The CR95 scenario also reduced the daytime surface urban heat island by up to 5.26 °C. The inter-LCZ assessment showed that CR95 reduced air temperature by up to 0.93 °C in compact low-rise areas (LCZ 3) and 0.98 °C in open high-rise areas (LCZ 4), demonstrating the potential of cool-roof retrofits to mitigate extreme heat in arid cities. Sensible heat flux was lower in the cool roof scenarios (70–130 W/m 2 ) than in the green roof scenarios (20–100 W/m 2 ), compared to the base case. Green roofs produced lower temperature reductions but increased latent heat flux and may provide additional co-benefits. Overall, this study provides a comparison of rooftop heat mitigation effectiveness during the selected heatwave, while broader planning applications require assessment across additional meteorological conditions and validation through real-world implementation.

Frontiers in Environmental ScienceVol. 14
National Institute of Technology Rourkela (IN), King Abdullah University of Science and Technology (SA), The University of Texas at Austin (US)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon