Reference values for refractive error of the Spot Vision Screener in children under 3 years of age

Purpose To compare manufacturer and referral criteria for the Spot Vision Screener (SVS) for refractive errors and investigate the optimal cutoff value for patients under 3 years of age using the Youden index (YI). Study design Retrospective study. Methods Patients who presented from February 2016 to March 2024 were screened using the SVS before examination by pediatric ophthalmologists masked to the SVS results. All children underwent a comprehensive eye examination, including cycloplegic refraction. Participants were subdivided by age (6–11, 12–35, and 36–47 months) to determine gold standard results according to American Academy of Ophthalmology guidelines. The SVS effectiveness was compared by age group between the manufacturer and referral criteria. We evaluated the sensitivity and specificity of the cutoff value and investigated the cutoff value that maximizes the YI. Results Five hundred three children were included. The sensitivity and specificity of the SVS using manufacturer criteria were both 84.1% while using referral criteria they were 71.0% and 93.9%, respectively. False positives decreased in all categories using referral criteria. Most false-negative cases were astigmatism and hyperopia. Regarding anisometropia among 12-35 months old children, the cutoff value that maximized the YI improved specificity without compromising sensitivity. Conclusion The SVS demonstrated good sensitivity and specificity for detecting amblyopia risk factors in children under 3 years of age. Both manufacturer and referral criteria are clinically useful but should be selected based on whether the sensitivity or specificity is prioritized in each screening context. The cutoff value using the YI may contribute to improving the SVS criteria.

Authors

Publication Details

Journal
Japanese Journal of Ophthalmology
Published
2026-11-19
DOI
https://doi.org/10.1007/s10384-026-01459-5
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reference values for refractive error of the Spot Vision Screener in children under 3 years of age

Yuichi Hori, Saiko Matsumura, Sachiko Nishina, Hazuki Anzai et al.
Japanese Journal of Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Reference values for refractive error of the Spot Vision Screener in children under 3 years of age

Yuichi Hori, Saiko Matsumura, Sachiko Nishina, Hazuki Anzai, Yoko Kunugi, Tomoyo Yoshida, Tadashi Matsumoto, Mami Matsuoka
article en

Abstract

Purpose To compare manufacturer and referral criteria for the Spot Vision Screener (SVS) for refractive errors and investigate the optimal cutoff value for patients under 3 years of age using the Youden index (YI). Study design Retrospective study. Methods Patients who presented from February 2016 to March 2024 were screened using the SVS before examination by pediatric ophthalmologists masked to the SVS results. All children underwent a comprehensive eye examination, including cycloplegic refraction. Participants were subdivided by age (6–11, 12–35, and 36–47 months) to determine gold standard results according to American Academy of Ophthalmology guidelines. The SVS effectiveness was compared by age group between the manufacturer and referral criteria. We evaluated the sensitivity and specificity of the cutoff value and investigated the cutoff value that maximizes the YI. Results Five hundred three children were included. The sensitivity and specificity of the SVS using manufacturer criteria were both 84.1% while using referral criteria they were 71.0% and 93.9%, respectively. False positives decreased in all categories using referral criteria. Most false-negative cases were astigmatism and hyperopia. Regarding anisometropia among 12-35 months old children, the cutoff value that maximized the YI improved specificity without compromising sensitivity. Conclusion The SVS demonstrated good sensitivity and specificity for detecting amblyopia risk factors in children under 3 years of age. Both manufacturer and referral criteria are clinically useful but should be selected based on whether the sensitivity or specificity is prioritized in each screening context. The cutoff value using the YI may contribute to improving the SVS criteria.

Japanese Journal of Ophthalmology
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon