Current Clinical Practice and Barriers to Instrumented Gait Assessment in Stroke Rehabilitation: A Cross-Sectional Survey

Background Observational gait analysis is widely used in stroke rehabilitation but may have limited objectivity and reproducibility. Instrumented gait assessment may address these limitations, but its routine use and implementation barriers remain unclear. Objectives To investigate gait assessment practices and barriers to routine instrumented gait assessment among physiotherapists treating people with stroke. Methods A web-based cross-sectional survey was conducted among members of the Japanese Society of Neurological Physical Therapy. Respondents reporting limitations in observational gait analysis completed additional questions on instrumented gait assessment. Logistic regression examined factors associated with perceived measurement time burden among device users. Results Of 329 respondents, 95.4% used standardized clinical gait assessments, and 81.8% perceived limitations in observational gait analysis. Although 91.2% recognized the need for instrumented gait assessment, only 39.8% of the 269 respondents completing the second-stage questions used it routinely. Of 162 non-users, 80.2% reported that relevant equipment was unavailable. Device users commonly reported excessive measurement time, high equipment costs, and difficulty interpreting results. Measurement time ≥20 min was associated with perceived measurement time burden (odds ratio 3.59, 95% confidence interval 1.04–12.46; p = 0.044). Automated analysis (95.5%) and usability regardless of location (83.6%) were frequently desired. Conclusions Instrumented gait assessment was widely perceived as necessary, but routine use remained limited. Improving equipment access and developing time-efficient, portable systems with automated analysis and interpretation support may facilitate integration into routine stroke rehabilitation and sustained clinical use.

Authors

Institutions

Publication Details

Journal
Neurorehabilitation
Published
2026-11-19
DOI
https://doi.org/10.1177/10538135261501052
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Current Clinical Practice and Barriers to Instrumented Gait Assessment in Stroke Rehabilitation: A Cross-Sectional Survey

Takaaki Ikeda, Manabu Nakamura, Masanori Wakida, Sota Araki et al.
Neurorehabilitation
Stroke Rehabilitation and Recovery
article

Current Clinical Practice and Barriers to Instrumented Gait Assessment in Stroke Rehabilitation: A Cross-Sectional Survey

Takaaki Ikeda, Manabu Nakamura, Masanori Wakida, Sota Araki, Naomichi Mizuta, Keita HONDA, Yusuke Sekiguchi, Ryosuke Kitatani, Hiroki Kubo, Yoshimi Suzukamo, Masataka Yamamoto, Tadashi Takahashi
article en

Abstract

Background Observational gait analysis is widely used in stroke rehabilitation but may have limited objectivity and reproducibility. Instrumented gait assessment may address these limitations, but its routine use and implementation barriers remain unclear. Objectives To investigate gait assessment practices and barriers to routine instrumented gait assessment among physiotherapists treating people with stroke. Methods A web-based cross-sectional survey was conducted among members of the Japanese Society of Neurological Physical Therapy. Respondents reporting limitations in observational gait analysis completed additional questions on instrumented gait assessment. Logistic regression examined factors associated with perceived measurement time burden among device users. Results Of 329 respondents, 95.4% used standardized clinical gait assessments, and 81.8% perceived limitations in observational gait analysis. Although 91.2% recognized the need for instrumented gait assessment, only 39.8% of the 269 respondents completing the second-stage questions used it routinely. Of 162 non-users, 80.2% reported that relevant equipment was unavailable. Device users commonly reported excessive measurement time, high equipment costs, and difficulty interpreting results. Measurement time ≥20 min was associated with perceived measurement time burden (odds ratio 3.59, 95% confidence interval 1.04–12.46; p = 0.044). Automated analysis (95.5%) and usability regardless of location (83.6%) were frequently desired. Conclusions Instrumented gait assessment was widely perceived as necessary, but routine use remained limited. Improving equipment access and developing time-efficient, portable systems with automated analysis and interpretation support may facilitate integration into routine stroke rehabilitation and sustained clinical use.

Neurorehabilitation
Tohoku Fukushi University (JP), Yamagata University (JP), Nihon Fukushi University (JP), Kansai Medical University (JP), Ritsumeikan University (JP), Kumamoto Health Science University (JP), Konan Women's University (JP), Tohoku University (JP), Ebara Hospital (JP), Saiseikai Yokohama Eastern Hospital (JP), Niigata University of Health and Welfare (JP), Tokyo University of Agriculture and Technology (JP)
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon