Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology

Background: Mechanical haemolysis is a rare complication of modified Blalock–Thomas–Taussig shunt physiology. Abnormal shunt-related haemodynamics may generate pathologic shear forces resulting in clinically significant haemolysis, although this complication has been only rarely reported. Case presentation: A full-term infant with hypoplastic left heart syndrome underwent stage I Norwood palliation with placement of a 4.0-mm Gore-Tex modified Blalock–Thomas–Taussig shunt. The postoperative course was complicated by severe transfusion-dependent intravascular haemolysis, characterised by markedly elevated lactate dehydrogenase, plasma free haemoglobin, reticulocytosis, occasional schistocytes, and haemoglobinuria. A distinctive clinical feature was recurrent hypoxaemia that failed to improve with supplemental oxygen but consistently resolved following packed red blood cell transfusion. Extensive haematologic evaluation excluded alternative causes of haemolysis. Echocardiography demonstrated high-velocity flow across the shunt, while CT angiography revealed focal narrowing of the proximal innominate artery immediately proximal to the shunt origin, suggesting abnormal flow acceleration and increased shear stress. During the interstage period, the patient required 32 packed red blood cell transfusions. Following Hemi-Fontan completion with shunt takedown at 6 months of age, haemolysis resolved completely, and no further transfusions were required during hospitalisation or outpatient follow-up. Conclusions: Proximal innominate artery narrowing associated with a modified Blalock–Thomas–Taussig shunt may exacerbate shunt-related shear stress, resulting in clinically significant mechanical haemolysis and recurrent transfusion-responsive hypoxaemia despite preserved shunt patency. Mechanical haemolysis should be considered in infants with unexplained transfusion-dependent anaemia following systemic-to-pulmonary shunt placement.

Authors

Publication Details

Journal
Cardiology in the Young
Published
2026-11-19
DOI
https://doi.org/10.1017/s1047951126125086
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology

Nayan T. Srivastava, Wail Ali, Mark D. Rodefeld
Cardiology in the Young
Congenital Heart Disease Studies
article

Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology

Nayan T. Srivastava, Wail Ali, Mark D. Rodefeld
article en

Abstract

Background: Mechanical haemolysis is a rare complication of modified Blalock–Thomas–Taussig shunt physiology. Abnormal shunt-related haemodynamics may generate pathologic shear forces resulting in clinically significant haemolysis, although this complication has been only rarely reported. Case presentation: A full-term infant with hypoplastic left heart syndrome underwent stage I Norwood palliation with placement of a 4.0-mm Gore-Tex modified Blalock–Thomas–Taussig shunt. The postoperative course was complicated by severe transfusion-dependent intravascular haemolysis, characterised by markedly elevated lactate dehydrogenase, plasma free haemoglobin, reticulocytosis, occasional schistocytes, and haemoglobinuria. A distinctive clinical feature was recurrent hypoxaemia that failed to improve with supplemental oxygen but consistently resolved following packed red blood cell transfusion. Extensive haematologic evaluation excluded alternative causes of haemolysis. Echocardiography demonstrated high-velocity flow across the shunt, while CT angiography revealed focal narrowing of the proximal innominate artery immediately proximal to the shunt origin, suggesting abnormal flow acceleration and increased shear stress. During the interstage period, the patient required 32 packed red blood cell transfusions. Following Hemi-Fontan completion with shunt takedown at 6 months of age, haemolysis resolved completely, and no further transfusions were required during hospitalisation or outpatient follow-up. Conclusions: Proximal innominate artery narrowing associated with a modified Blalock–Thomas–Taussig shunt may exacerbate shunt-related shear stress, resulting in clinically significant mechanical haemolysis and recurrent transfusion-responsive hypoxaemia despite preserved shunt patency. Mechanical haemolysis should be considered in infants with unexplained transfusion-dependent anaemia following systemic-to-pulmonary shunt placement.

Cardiology in the Young
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon