Optimization of an EMAT with a magnetic flux concentrator for in-pipe wall-thickness inspection

Electromagnetic acoustic transducers (EMATs) used for in-pipe wall-thickness inspection often exhibit low transduction efficiency and limited echo sensitivity. To address this limitations, a magnetic flux concentrator (MFC) is introduced as a key structural component to enhance the bias magnetic field distribution. In this study, an EMAT design incorporating an MFC is proposed for confined in-pipe inspection. The effects of MFC geometry and material properties on magnetic field distribution and transduction performance are systematically investigated using orthogonal-design-based multiphysics simulations, followed by experimental validation. The results indicate that the MFC height and short-edge width are the dominant geometric factors, while long-edge width has a smaller influence. Under the strong bias-field conditions considered, silicon steel performs better than permalloy because of its higher saturation magnetic flux density. With the optimal configuration, the echo amplitude increase by approximately 34%, the thickness measurement error decreases to 0.12%, and the magnetic attraction force is simultaneously decreased. These results demonstrate that MFC-based magnetic circuit optimisation provides an effective and practical approach for improving EMAT performance in confined in-pipe inspection applications.

Authors

Institutions

Publication Details

Journal
Nondestructive Testing And Evaluation
Published
2026-11-18
DOI
https://doi.org/10.1080/10589759.2026.2762506
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimization of an EMAT with a magnetic flux concentrator for in-pipe wall-thickness inspection

Jingwei Cheng, Xiaokang Wan, Shuhao Ma, Zhe Wang et al.
Nondestructive Testing And Evaluation
Ultrasonics and Acoustic Wave Propagation
article

Optimization of an EMAT with a magnetic flux concentrator for in-pipe wall-thickness inspection

Jingwei Cheng, Xiaokang Wan, Shuhao Ma, Zhe Wang, Jian Tang, Shuyang Ao
article en

Abstract

Electromagnetic acoustic transducers (EMATs) used for in-pipe wall-thickness inspection often exhibit low transduction efficiency and limited echo sensitivity. To address this limitations, a magnetic flux concentrator (MFC) is introduced as a key structural component to enhance the bias magnetic field distribution. In this study, an EMAT design incorporating an MFC is proposed for confined in-pipe inspection. The effects of MFC geometry and material properties on magnetic field distribution and transduction performance are systematically investigated using orthogonal-design-based multiphysics simulations, followed by experimental validation. The results indicate that the MFC height and short-edge width are the dominant geometric factors, while long-edge width has a smaller influence. Under the strong bias-field conditions considered, silicon steel performs better than permalloy because of its higher saturation magnetic flux density. With the optimal configuration, the echo amplitude increase by approximately 34%, the thickness measurement error decreases to 0.12%, and the magnetic attraction force is simultaneously decreased. These results demonstrate that MFC-based magnetic circuit optimisation provides an effective and practical approach for improving EMAT performance in confined in-pipe inspection applications.

Nondestructive Testing And Evaluation
Hefei General Machinery Research Institute (China) (CN), Zhejiang University of Technology (CN)
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon