Boron-Nitride-Doped Graphene Oxide FETs for COVID-19 Detection: A Comparative Review Against Existing Market Solutions

COVID-19 point-of-care tests return results faster than centralized RT-PCR, but none combines high sensitivity, speed, low cost, and ease of use. This review compares a boron-nitride-doped graphene oxide (BN-GO) FET biosensor with commercial diagnostics and other graphene-based FET biosensors using LOD, PPA/NPA, detection time, cost, shelf life, and ease of use. Because the BN-GO platform is at technology readiness level 4 and has been tested only in buffer, the market comparison is treated as a gap analysis. The BN-GO FET biosensor showed promising early-stage analytical performance, responding rapidly to N-protein in buffer at its lowest tested concentration, below the detection limits of the other graphene FETs compared. However, the lowest-concentration response was obtained from an initial set of device tests. Future studies will assess the repeatability, reproducibility, clinical performance, and manufacturing scalability of the device. They will also focus on extending its shelf life, because the current estimate falls short of the WHO target product profile and would complicate stockpiling and distribution. The estimated cost per test is approximately the same as that of rapid antigen tests. These findings position the BN-GO FET biosensor as a promising next-generation candidate for point-of-care COVID-19 diagnostics if the remaining cost and shelf-life challenges are addressed.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-11-19
DOI
https://doi.org/10.3390/ma19224907
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Boron-Nitride-Doped Graphene Oxide FETs for COVID-19 Detection: A Comparative Review Against Existing Market Solutions

Michal Bajcsy, Alexander H. Xu, Saeed Takaloo, Liena Zaidan et al.
Materials
Electrochemical sensors and biosensors
article

Boron-Nitride-Doped Graphene Oxide FETs for COVID-19 Detection: A Comparative Review Against Existing Market Solutions

Michal Bajcsy, Alexander H. Xu, Saeed Takaloo, Liena Zaidan, Bersu Baştuğ Azer, Mustafa Yavuz, Dogu Kaan Bugra Ozyigit
article en

Abstract

COVID-19 point-of-care tests return results faster than centralized RT-PCR, but none combines high sensitivity, speed, low cost, and ease of use. This review compares a boron-nitride-doped graphene oxide (BN-GO) FET biosensor with commercial diagnostics and other graphene-based FET biosensors using LOD, PPA/NPA, detection time, cost, shelf life, and ease of use. Because the BN-GO platform is at technology readiness level 4 and has been tested only in buffer, the market comparison is treated as a gap analysis. The BN-GO FET biosensor showed promising early-stage analytical performance, responding rapidly to N-protein in buffer at its lowest tested concentration, below the detection limits of the other graphene FETs compared. However, the lowest-concentration response was obtained from an initial set of device tests. Future studies will assess the repeatability, reproducibility, clinical performance, and manufacturing scalability of the device. They will also focus on extending its shelf life, because the current estimate falls short of the WHO target product profile and would complicate stockpiling and distribution. The estimated cost per test is approximately the same as that of rapid antigen tests. These findings position the BN-GO FET biosensor as a promising next-generation candidate for point-of-care COVID-19 diagnostics if the remaining cost and shelf-life challenges are addressed.

MaterialsVol. 19(22)
University of Waterloo (CA)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon