Role of 2D speckle-tracking echocardiography in detecting acute coronary occlusion in patients with non-ST-segment elevation myocardial infarction

Introduction Two-dimensional speckle-tracking echocardiography (2D STE) enables quantitative assessment of regional and global left ventricular function and may assist in identifying patients with acute coronary occlusion. This study aimed to evaluate the association and diagnostic performance of 2D STE-derived global longitudinal strain (GLS) in patients with non-ST-segment elevation myocardial infarction (NSTEMI). Patients and methods This prospective observational study included 50 patients with NSTEMI admitted to the coronary care unit of Damietta Cardiology Center. Patients were classified as having normal GLS (≤-16%) or impaired GLS (>-16%). All patients underwent clinical assessment, electrocardiography, laboratory testing, transthoracic echocardiography, 2D STE, and coronary angiography. Results GLS was less negative in patients with total than partial coronary occlusion (-8.8 ± 5.24% vs. -12.16 ± 4.91%, P =0.038); however, its ROC performance for total occlusion was not statistically significant (AUC=0.52, P =0.08). Ejection fraction and left ventricular internal diameters differed significantly between the GLS groups (Welch’s t test, P <0.001 for each comparison). SYNTAX and GRACE scores also differed ( P <0.001 and P =0.003, respectively), as did Killip class ( P =0.001), whereas length of stay did not ( P =0.079). GLS values were significantly less negative among patients who required mechanical ventilation or vasopressor support and among non-survivors ( P =0.001 for each comparison). Conclusion In this cohort, GLS was associated with ventricular dysfunction and markers of clinical severity. Although GLS differed between total- and partial-occlusion groups, it did not demonstrate significant discrimination of total occlusion in this small cohort and should not be used as a stand-alone diagnostic test.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Critical Care Medicine
Published
2026-11-19
DOI
https://doi.org/10.1007/s44349-026-00065-1
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Role of 2D speckle-tracking echocardiography in detecting acute coronary occlusion in patients with non-ST-segment elevation myocardial infarction

Shreen Mostafa El Gengehy, Nora Ismail Mohamad Abbas, Shady Hussein Mohammad, Nadia Mosbah Mohamed Hassan
The Egyptian Journal of Critical Care Medicine
Cardiovascular Function and Risk Factors
article

Role of 2D speckle-tracking echocardiography in detecting acute coronary occlusion in patients with non-ST-segment elevation myocardial infarction

Shreen Mostafa El Gengehy, Nora Ismail Mohamad Abbas, Shady Hussein Mohammad, Nadia Mosbah Mohamed Hassan
article en

Abstract

Introduction Two-dimensional speckle-tracking echocardiography (2D STE) enables quantitative assessment of regional and global left ventricular function and may assist in identifying patients with acute coronary occlusion. This study aimed to evaluate the association and diagnostic performance of 2D STE-derived global longitudinal strain (GLS) in patients with non-ST-segment elevation myocardial infarction (NSTEMI). Patients and methods This prospective observational study included 50 patients with NSTEMI admitted to the coronary care unit of Damietta Cardiology Center. Patients were classified as having normal GLS (≤-16%) or impaired GLS (>-16%). All patients underwent clinical assessment, electrocardiography, laboratory testing, transthoracic echocardiography, 2D STE, and coronary angiography. Results GLS was less negative in patients with total than partial coronary occlusion (-8.8 ± 5.24% vs. -12.16 ± 4.91%, P =0.038); however, its ROC performance for total occlusion was not statistically significant (AUC=0.52, P =0.08). Ejection fraction and left ventricular internal diameters differed significantly between the GLS groups (Welch’s t test, P <0.001 for each comparison). SYNTAX and GRACE scores also differed ( P <0.001 and P =0.003, respectively), as did Killip class ( P =0.001), whereas length of stay did not ( P =0.079). GLS values were significantly less negative among patients who required mechanical ventilation or vasopressor support and among non-survivors ( P =0.001 for each comparison). Conclusion In this cohort, GLS was associated with ventricular dysfunction and markers of clinical severity. Although GLS differed between total- and partial-occlusion groups, it did not demonstrate significant discrimination of total occlusion in this small cohort and should not be used as a stand-alone diagnostic test.

The Egyptian Journal of Critical Care MedicineVol. 13(1)
Cairo University (EG), Mansoura University (EG)
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon