Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga

External strengthening using fibre-reinforced polymer (FRP) is widely adopted to enhance the flexural capacity of reinforced concrete (RC) T-beams. However, brittle failure modes triggered by premature debonding remain a major challenge in structural modelling. This comparative review aims to evaluate and synthesise the agreement between finite element modelling (FEM) predictions and experimental results for RC T-beams strengthened with hybrid FRP (HFRP) and carbon FRP (CFRP) across varied strengthening configurations. A quantitative assessment was conducted on four parameters: ultimate load capacity (Pmax), critical deflections (δy, δmax, δu), displacement ductility (μΔ), and dissipated energy (Ed). The synthesis confirms that external FRP strengthening consistently increases experimental peak loads (for instance, from 236.0 kN to 291.0 kN), yet exerts opposing effects on peak deflection depending on the strengthening layout and bonded span length. The flexural capacity gains are generally accompanied by a 9-56% reduction in experimental ductility compared with control specimens, whereas transverse strip configurations preserve ductility more effectively and absorb 18-73% more energy (0.91-1.12 kJ) than full-width plates (0.65-0.77 kJ). Regarding numerical validation, FEM simulations predict ultimate load capacities with high accuracy against physical tests (such as 208.5 kN vs. 210.0 kN for BFR1 and 301.0 kN vs. 297.0 kN for SB2), but overestimate initial elastic stiffness, resulting in substantially smaller yield deflections (δy). Owing to the perfect-bond assumption that neglects post-peak brittle delamination, standard FEM analyses overestimate ductility indices (μFEM/μEksp reaching 1.12-2.32) and yield 4.13- 45.89% higher dissipated energy across most specimens. These findings underscore the necessity of incorporating cohesive zone modelling at the concrete-FRP interface to capture actual brittle failure accurately.

Authors

Institutions

Publication Details

Journal
Journal of Infrastructure and Construction Technology
Published
2026-11-20
DOI
https://doi.org/10.56208/jictech.4.2.1-20
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga

Ridwan Ridwan, M. Khairi Ihsan
Journal of Infrastructure and Construction Technology
Structural Behavior of Reinforced Concrete
article

Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga

Ridwan Ridwan, M. Khairi Ihsan
article en

Abstract

External strengthening using fibre-reinforced polymer (FRP) is widely adopted to enhance the flexural capacity of reinforced concrete (RC) T-beams. However, brittle failure modes triggered by premature debonding remain a major challenge in structural modelling. This comparative review aims to evaluate and synthesise the agreement between finite element modelling (FEM) predictions and experimental results for RC T-beams strengthened with hybrid FRP (HFRP) and carbon FRP (CFRP) across varied strengthening configurations. A quantitative assessment was conducted on four parameters: ultimate load capacity (Pmax), critical deflections (δy, δmax, δu), displacement ductility (μΔ), and dissipated energy (Ed). The synthesis confirms that external FRP strengthening consistently increases experimental peak loads (for instance, from 236.0 kN to 291.0 kN), yet exerts opposing effects on peak deflection depending on the strengthening layout and bonded span length. The flexural capacity gains are generally accompanied by a 9-56% reduction in experimental ductility compared with control specimens, whereas transverse strip configurations preserve ductility more effectively and absorb 18-73% more energy (0.91-1.12 kJ) than full-width plates (0.65-0.77 kJ). Regarding numerical validation, FEM simulations predict ultimate load capacities with high accuracy against physical tests (such as 208.5 kN vs. 210.0 kN for BFR1 and 301.0 kN vs. 297.0 kN for SB2), but overestimate initial elastic stiffness, resulting in substantially smaller yield deflections (δy). Owing to the perfect-bond assumption that neglects post-peak brittle delamination, standard FEM analyses overestimate ductility indices (μFEM/μEksp reaching 1.12-2.32) and yield 4.13- 45.89% higher dissipated energy across most specimens. These findings underscore the necessity of incorporating cohesive zone modelling at the concrete-FRP interface to capture actual brittle failure accurately.

Journal of Infrastructure and Construction TechnologyVol. 4(2)
Riau University (ID)
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon