Efficient and Enhanced Signal Quality Assessment for EDA Wearables

Electrodermal activity (EDA) is a widely used marker of sympathetic arousal and stress, in both daily-life and clinical monitoring, but EDA signals from wearable devices are frequently degraded by artifacts, and expert-labeled data for quality assessment are scarce. We present a lightweight EDA signal quality index (SQI) system that uses unsupervised pre-training to reduce reliance on labeled data. The model is first pre-trained on unsupervised denoising and forecasting tasks, then fine-tuned using a publicly available expert-labeled dataset. On the EDABE benchmark, our method achieves a mean ROC-AUC of 0.851 and a mean AUPRC of 0.494, improvements of 8% and 18.5%, respectively, over the strongest baseline. The model also generalizes across devices, body locations, and types of motion: applied zero-shot to AffectiveROAD, wrist-worn Empatica E4 recordings from real-world driving (whereas training used finger-worn sensors), it achieves a ROC-AUC of 0.740, a 7.9% improvement over the same network trained from scratch, using high wrist acceleration as the reference for motion artifacts. The model requires 3.9 MFLOPs per inference. These results show that unsupervised pre-training improves performance, enabling scalable, low-power EDA quality assessment for continuous wearable monitoring.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-11-19
DOI
https://doi.org/10.3390/bioengineering13111388
Primary Topic
Emotion and Mood Recognition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Efficient and Enhanced Signal Quality Assessment for EDA Wearables

Nicholas J. Huang, Linda M. Eerikäinen, Octavian Cota, Mark van Gastel et al.
Bioengineering
Emotion and Mood Recognition
article

Efficient and Enhanced Signal Quality Assessment for EDA Wearables

Nicholas J. Huang, Linda M. Eerikäinen, Octavian Cota, Mark van Gastel, Luoluo Liu
article en

Abstract

Electrodermal activity (EDA) is a widely used marker of sympathetic arousal and stress, in both daily-life and clinical monitoring, but EDA signals from wearable devices are frequently degraded by artifacts, and expert-labeled data for quality assessment are scarce. We present a lightweight EDA signal quality index (SQI) system that uses unsupervised pre-training to reduce reliance on labeled data. The model is first pre-trained on unsupervised denoising and forecasting tasks, then fine-tuned using a publicly available expert-labeled dataset. On the EDABE benchmark, our method achieves a mean ROC-AUC of 0.851 and a mean AUPRC of 0.494, improvements of 8% and 18.5%, respectively, over the strongest baseline. The model also generalizes across devices, body locations, and types of motion: applied zero-shot to AffectiveROAD, wrist-worn Empatica E4 recordings from real-world driving (whereas training used finger-worn sensors), it achieves a ROC-AUC of 0.740, a 7.9% improvement over the same network trained from scratch, using high wrist acceleration as the reference for motion artifacts. The model requires 3.9 MFLOPs per inference. These results show that unsupervised pre-training improves performance, enabling scalable, low-power EDA quality assessment for continuous wearable monitoring.

BioengineeringVol. 13(11)
Philips (Netherlands) (NL), Signify (Netherlands) (NL), Eindhoven University of Technology (NL)
Emotion and Mood Recognition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon