Low-Cost Esp32 Environmental Sensing Node with Cloud Alerting for Allergy-Relevant Conditions: A Documented Baseline

We describe a low-cost ESP32 node that combines a BME280 (temperature, humidity, pressure) and an MQ135 gas sensor. It shows readings on a 16×2 LCD, uploads them every 30 s to the Blynk IoT cloud, and logs a cloud event when the raw gas reading crosses a threshold. The node screens for conditions associated with allergic respiratory symptoms through proxy variables; it does not detect or count pollen. In a four-site preliminary survey (home, park, traffic junction, construction site), the gas index was 59 to 90 at the two low-traffic sites and 270 to 290 at the two polluted ones. With one reading per site, only descriptive values are reported. We document the implementation for replication, state what proxy sensing can and cannot support, and give a validation protocol for a follow-up study.

Authors

Publication Details

Journal
International Journal of Advanced Research in Science Communication and Technology
Published
2026-11-19
DOI
https://doi.org/10.48175/ijarsct-40868
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Low-Cost Esp32 Environmental Sensing Node with Cloud Alerting for Allergy-Relevant Conditions: A Documented Baseline

Rayhan Hameed, Darius A, Monish S
International Journal of Advanced Research in Science Communication and Technology
Air Quality Monitoring and Forecasting
article

Low-Cost Esp32 Environmental Sensing Node with Cloud Alerting for Allergy-Relevant Conditions: A Documented Baseline

Rayhan Hameed, Darius A, Monish S
article en

Abstract

We describe a low-cost ESP32 node that combines a BME280 (temperature, humidity, pressure) and an MQ135 gas sensor. It shows readings on a 16×2 LCD, uploads them every 30 s to the Blynk IoT cloud, and logs a cloud event when the raw gas reading crosses a threshold. The node screens for conditions associated with allergic respiratory symptoms through proxy variables; it does not detect or count pollen. In a four-site preliminary survey (home, park, traffic junction, construction site), the gas index was 59 to 90 at the two low-traffic sites and 270 to 290 at the two polluted ones. With one reading per site, only descriptive values are reported. We document the implementation for replication, state what proxy sensing can and cannot support, and give a validation protocol for a follow-up study.

International Journal of Advanced Research in Science Communication and Technology
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon