Near-Field Electromagnetic Coupling, Transient Percolation Holds, and Non-Ohmic Negative Differential Resistance in Inverted Coaxial Mingraph Flexible Graphite Tri-Laminates
Flexible carbon-metal tri-laminated coaxial cylinders offer a lightweight, dual-function architecture combining non-Ohmic surge clamping with near-field electromagnetic interference (EMI) attenuation. In this study, an inverted hollow cylindrical tri-laminate was fabricated using an outer isotropic copper foil layer, a middle 0.05 mm Mingraph flexible exfoliated graphite sheet (EGS, Mineral Seal Corporation) core, and an inner isotropic nickel/copper-plated Faraday conductive cloth lumen, externally encapsulated with electrically insulating Kapton polyimide film. Direct-current (DC) constant-current step sweeps (1.30 A to 8.30 A, 1.0 A increments, 4 s dwell) were performed in series with a benchtop DC power supply and a ZKE Tech programmable DC electronic load, applying a standardized R_baseline = 0.1428 ohm fixture-and-lead correction at every step. Across all sweeps, the inverted coaxial unit exhibited pronounced Negative Differential Resistance (NDR, dV/dI < 0), with baseline-corrected static resistance (R_corr) collapsing by 98.99% to 99.44% (from 1.8418 ohm at 1.30 A down to 0.0102–0.0186 ohm at 8.30 A) and incremental non-linearity exponents reaching alpha_inc = -4.075. To isolate near-field electromagnetic coupling, the floating, Kapton-insulated cylinder was placed in direct orthogonal contact against the metallic chassis of a running brushed DC motor powered by a 3.7 V lithium-ion power bank stepped up to 5.0 V. Immediately following 30 s of active motor contact, the step sweep exhibited a downward voltage shift (-0.02 V to -0.05 V) and a transient step-logging hold at 4.30 A / 1.97 V across two consecutive indices (skipping 5.30 A), followed by full monotonic recovery and dielectric rebound (+0.01 V to +0.05 V) on the immediate subsequent sweep. Crucially, a 120 s sham-contact control against the unpowered (motor-OFF) chassis produced zero step holds and smooth monotonic progression across all eight steps, ruling out mechanical or thermal contact artifacts and confirming active EMI interaction. These findings establish the experimental baseline for upcoming battery-operated oscilloscope time-domain and spectral EMI filtering measurements.
Authors
- David S. Soriano
Institutions
- University of Pittsburgh (US)
- University of Pittsburgh at Bradford (US)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-19
- DOI
- https://doi.org/10.5281/zenodo.24381446
- Primary Topic
- Electromagnetic wave absorption materials
- Type
- preprint