Near-Field Electromagnetic Coupling, Transient Percolation Holds, and Non-Ohmic Negative Differential Resistance in Inverted Coaxial Mingraph Flexible Graphite Tri-Laminates

Flexible carbon-metal tri-laminated coaxial cylinders offer a lightweight, dual-function architecture combining non-Ohmic surge clamping with near-field electromagnetic interference (EMI) attenuation. In this study, an inverted hollow cylindrical tri-laminate was fabricated using an outer isotropic copper foil layer, a middle 0.05 mm Mingraph flexible exfoliated graphite sheet (EGS, Mineral Seal Corporation) core, and an inner isotropic nickel/copper-plated Faraday conductive cloth lumen, externally encapsulated with electrically insulating Kapton polyimide film. Direct-current (DC) constant-current step sweeps (1.30 A to 8.30 A, 1.0 A increments, 4 s dwell) were performed in series with a benchtop DC power supply and a ZKE Tech programmable DC electronic load, applying a standardized R_baseline = 0.1428 ohm fixture-and-lead correction at every step. Across all sweeps, the inverted coaxial unit exhibited pronounced Negative Differential Resistance (NDR, dV/dI < 0), with baseline-corrected static resistance (R_corr) collapsing by 98.99% to 99.44% (from 1.8418 ohm at 1.30 A down to 0.0102–0.0186 ohm at 8.30 A) and incremental non-linearity exponents reaching alpha_inc = -4.075. To isolate near-field electromagnetic coupling, the floating, Kapton-insulated cylinder was placed in direct orthogonal contact against the metallic chassis of a running brushed DC motor powered by a 3.7 V lithium-ion power bank stepped up to 5.0 V. Immediately following 30 s of active motor contact, the step sweep exhibited a downward voltage shift (-0.02 V to -0.05 V) and a transient step-logging hold at 4.30 A / 1.97 V across two consecutive indices (skipping 5.30 A), followed by full monotonic recovery and dielectric rebound (+0.01 V to +0.05 V) on the immediate subsequent sweep. Crucially, a 120 s sham-contact control against the unpowered (motor-OFF) chassis produced zero step holds and smooth monotonic progression across all eight steps, ruling out mechanical or thermal contact artifacts and confirming active EMI interaction. These findings establish the experimental baseline for upcoming battery-operated oscilloscope time-domain and spectral EMI filtering measurements.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-19
DOI
https://doi.org/10.5281/zenodo.24381446
Primary Topic
Electromagnetic wave absorption materials
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Near-Field Electromagnetic Coupling, Transient Percolation Holds, and Non-Ohmic Negative Differential Resistance in Inverted Coaxial Mingraph Flexible Graphite Tri-Laminates

David S. Soriano
Zenodo (CERN European Organization for Nuclear Research)
Electromagnetic wave absorption materials
preprint

Near-Field Electromagnetic Coupling, Transient Percolation Holds, and Non-Ohmic Negative Differential Resistance in Inverted Coaxial Mingraph Flexible Graphite Tri-Laminates

David S. Soriano
preprint en

Abstract

Flexible carbon-metal tri-laminated coaxial cylinders offer a lightweight, dual-function architecture combining non-Ohmic surge clamping with near-field electromagnetic interference (EMI) attenuation. In this study, an inverted hollow cylindrical tri-laminate was fabricated using an outer isotropic copper foil layer, a middle 0.05 mm Mingraph flexible exfoliated graphite sheet (EGS, Mineral Seal Corporation) core, and an inner isotropic nickel/copper-plated Faraday conductive cloth lumen, externally encapsulated with electrically insulating Kapton polyimide film. Direct-current (DC) constant-current step sweeps (1.30 A to 8.30 A, 1.0 A increments, 4 s dwell) were performed in series with a benchtop DC power supply and a ZKE Tech programmable DC electronic load, applying a standardized R_baseline = 0.1428 ohm fixture-and-lead correction at every step. Across all sweeps, the inverted coaxial unit exhibited pronounced Negative Differential Resistance (NDR, dV/dI < 0), with baseline-corrected static resistance (R_corr) collapsing by 98.99% to 99.44% (from 1.8418 ohm at 1.30 A down to 0.0102–0.0186 ohm at 8.30 A) and incremental non-linearity exponents reaching alpha_inc = -4.075. To isolate near-field electromagnetic coupling, the floating, Kapton-insulated cylinder was placed in direct orthogonal contact against the metallic chassis of a running brushed DC motor powered by a 3.7 V lithium-ion power bank stepped up to 5.0 V. Immediately following 30 s of active motor contact, the step sweep exhibited a downward voltage shift (-0.02 V to -0.05 V) and a transient step-logging hold at 4.30 A / 1.97 V across two consecutive indices (skipping 5.30 A), followed by full monotonic recovery and dielectric rebound (+0.01 V to +0.05 V) on the immediate subsequent sweep. Crucially, a 120 s sham-contact control against the unpowered (motor-OFF) chassis produced zero step holds and smooth monotonic progression across all eight steps, ruling out mechanical or thermal contact artifacts and confirming active EMI interaction. These findings establish the experimental baseline for upcoming battery-operated oscilloscope time-domain and spectral EMI filtering measurements.

Zenodo (CERN European Organization for Nuclear Research)
University of Pittsburgh (US), University of Pittsburgh at Bradford (US)
Electromagnetic wave absorption materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon