DYNAMIC ANALYSIS AND QUANTITATIVE FAULT CHARACTERISATION OFA THREE-PHASE INDUCTION MOTOR USING d-q TRANSFORMATIONAND MATLAB/Simulink

Three-phase induction motors are widely used in industrial drive systems, where electrical faults can produce significant disturbances in current, electromagnetic torque, and rotor speed. This study presents dynamic modelling and quantitative fault characterisation of a three-phase induction motor using the d-q transformation and MATLAB/Simulink. The developed model was used to investigate the motor under no-fault, three-phase symmetrical fault, and unsymmetrical line-to-ground (L-G), line-to-line (L-L), and double line-to-ground (L-L-G) fault conditions. The dynamic responses were evaluated using peak stator current, RMS stator current, minimum rotor speed, percentage speed reduction, minimum electromagnetic torque, peak-to-peak torque variation, and phase current imbalance. Under the no-fault condition, the motor attained a steady-state speed of approximately 1800 rpm. The three-phase fault resulted in a small speed reduction to approximately 1734.14 rpm and a minimum electromagnetic torque of −71.71 Nm. The L- G fault produced a comparatively smaller speed reduction to approximately 1764.10 rpm, although significant current and torque disturbances were observed. The L-L fault produced the highest peak stator current of approximately 226.62 A and the largest peak-to-peak torque variation of 319.49 Nm, while the L-LG fault produced the phase current imbalance of 70.69%. The results demonstrate that fault severity is dependent on the performance metric considered and that no single dynamic variable is sufficient to comprehensively characterise induction-motor fault behaviour. The proposed quantitative fault characterisation provides useful complementary dynamic indicators for quantitative comparison of induction motor fault responses and provides a simulation-based foundation for subsequent condition monitoring and fault classification studies.

Authors

Institutions

Publication Details

Journal
FULafia Journal of Science and Technology
Published
2026-11-19
DOI
https://doi.org/10.62050/fjst2027.v11n1.880
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DYNAMIC ANALYSIS AND QUANTITATIVE FAULT CHARACTERISATION OFA THREE-PHASE INDUCTION MOTOR USING d-q TRANSFORMATIONAND MATLAB/Simulink

Ayo Isaac Oyedeji, Ignatius Kema Okakwu, Ayobami Taiwo Olusesi, Ayodeji Joseph Akinremi et al.
FULafia Journal of Science and Technology
Machine Fault Diagnosis Techniques
article

DYNAMIC ANALYSIS AND QUANTITATIVE FAULT CHARACTERISATION OFA THREE-PHASE INDUCTION MOTOR USING d-q TRANSFORMATIONAND MATLAB/Simulink

Ayo Isaac Oyedeji, Ignatius Kema Okakwu, Ayobami Taiwo Olusesi, Ayodeji Joseph Akinremi, Ayodeji Okubanjo
article en

Abstract

Three-phase induction motors are widely used in industrial drive systems, where electrical faults can produce significant disturbances in current, electromagnetic torque, and rotor speed. This study presents dynamic modelling and quantitative fault characterisation of a three-phase induction motor using the d-q transformation and MATLAB/Simulink. The developed model was used to investigate the motor under no-fault, three-phase symmetrical fault, and unsymmetrical line-to-ground (L-G), line-to-line (L-L), and double line-to-ground (L-L-G) fault conditions. The dynamic responses were evaluated using peak stator current, RMS stator current, minimum rotor speed, percentage speed reduction, minimum electromagnetic torque, peak-to-peak torque variation, and phase current imbalance. Under the no-fault condition, the motor attained a steady-state speed of approximately 1800 rpm. The three-phase fault resulted in a small speed reduction to approximately 1734.14 rpm and a minimum electromagnetic torque of −71.71 Nm. The L- G fault produced a comparatively smaller speed reduction to approximately 1764.10 rpm, although significant current and torque disturbances were observed. The L-L fault produced the highest peak stator current of approximately 226.62 A and the largest peak-to-peak torque variation of 319.49 Nm, while the L-LG fault produced the phase current imbalance of 70.69%. The results demonstrate that fault severity is dependent on the performance metric considered and that no single dynamic variable is sufficient to comprehensively characterise induction-motor fault behaviour. The proposed quantitative fault characterisation provides useful complementary dynamic indicators for quantitative comparison of induction motor fault responses and provides a simulation-based foundation for subsequent condition monitoring and fault classification studies.

FULafia Journal of Science and TechnologyVol. 11(1)
Olabisi Onabanjo University (NG)
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon