Continuity, not peak signal, should guide flip-angle optimization of slow-flow vertebral artery V3
Background and Purpose Three-dimensional time-of-flight MR angiography of the slow-flow vertebral artery V3 is conventionally optimized by maximizing signal-to-noise ratio or contrast-to-noise ratio, whether these indices predict reader-assessed depiction of a long, tortuous segment is unknown. We tested whether flip angle optimization guided by peak signal-to-noise ratio or contrast-to-noise ratio identifies the best V3 depiction and which metric drives reader-assessed depiction. Materials and Methods In this prospective study, 38 participants (21 women, 17 men; mean age 50.9 ± 11.3 years) underwent cervical 3D time-of-flight MR angiography at eight center flip angles (8°–25°; 18° routine) with otherwise identical parameters acquired in randomized order. Reader-assessed V3 depiction, signal-to-noise ratio, contrast-to-noise ratio, contrast-to-background ratio, the vertebral artery V3/internal carotid artery C3 ratio and proximal-to-distal V3 decay were measured; correlations and flip-angle × dominance interactions were analyzed. Results Vertebral artery V3 signal-to-noise ratio peaked at 16° (≈ 446) with no significant difference across 12°–20°, reader score fell from 12° and reader-assessed diagnostic adequacy dropped from 100% at 12° to 71.8% at 16° and 41.0% at 18° (both p < 0.01 versus 12°). Decay rose monotonically (8.4%–50.6%), exceeding 25% where scores collapsed. Reader score correlated with continuity (vertebral artery V3/internal carotid artery C3 ratio ρ ≈ 0.61, decay ρ ≈ −0.62) far more strongly than with signal-to-noise ratio (ρ ≈ 0.19) or contrast-to-noise ratio (ρ ≈ 0.12; 95% confidence interval includes 0). Conclusions For slow-flow vertebral artery V3, optimizing flip angle by peak signal-to-noise ratio or contrast-to-noise ratio is inadequate because these indices ignore intra-slab saturation; along-segment continuity which is quantified by proximal-to-distal decay or the vertebral artery V3/internal carotid artery C3 ratio and governed by Bloch recurrence is the endpoint that tracks reader depiction. A lower flip angle (approximately 12°) preserves V3 continuity without compromising fast-flow depiction. Reader-assessed V3 depiction scores peaked at 12° (4.75 ± 0.72) with 100% diagnostic adequacy, declining to 41.0% at 18° (p < 0.01 versus 12°).
Authors
- 曹红杰
- Zhao Dianjiang
- Xiuqin Jia (ORCID: https://orcid.org/0000-0003-3920-2884)
- Jiewen Qiu
- Shuitao Qiu
- Guijin Li
- Qi Yang
- Haishui Xie
Institutions
- Capital Medical University (CN)
- Beijing Chao-Yang Hospital, Capital Medical University (CN)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-19
- DOI
- https://doi.org/10.21203/rs.3.rs-11622771/v1
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- preprint