Hydraulic Performance Variation and Anti-clogging Regulatory Mechanisms of an Auto-flushing Emitter for Drip Irrigation under Sediment‑Laden Water Conditions

Emitter clogging severely limits drip irrigation using sediment-laden water. This study developed a novel auto-flushing emitter (AFE) with deformable elastomers, which switches between normal irrigation and auto‑flushing modes via pressure‑induced deformation that enlarges the flow cross‑section. Three emitter cores (EMI1, EMI2, EMI3) paired with three elastomers (silicone, SI; polyurethane, PU; non-deformable PTFE as the control, CK) were tested under clean water and sediment‑laden water (2 g/L, d50 = 34.84 µm). Under clean water, the AFE flow rate ( q CW ) increased stepwise with inlet pressure ( H 0 ), with an activation pressure threshold ( H j ) of 0.07–0.10 MPa. When H 0 > H j , q CW of the SI-fitted AFEs was 9.18–50.58% higher than that of the CKs. Under sediment‑laden water, the average relative discharge ( Dra ) of all nine emitters declined with operating time, but this decline weakened at higher H 0 and with softer elastomers. At 360 min, Dra of the SI-fitted AFEs exceeded PU-fitted and CKs by 14.2% and 30.2%, respectively. For AFEs, rising H 0 enlarged the flow cross-sectional area ( S ) and reduced mean flow velocity ( v ), whereas v increased in the CKs. Compared with PU-fitted AFEs and CKs, S of SI-fitted AFEs increased by 3.71–6.79% and 66.91–249.13%, respectively, and v (0.24–0.41 m/s) of the three SI-fitted AFEs overlapped the sediment incipient‑motion velocity (0.07–0.70 m/s). Correlation and regression analyses show that expanded S under auto-flushing is the primary driver of improved anti-clogging performance. These findings provide technical support for AFE development and sediment‑laden water drip‑irrigation application.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-19
DOI
https://doi.org/10.21203/rs.3.rs-11602371/v1
Primary Topic
Irrigation Practices and Water Management
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Hydraulic Performance Variation and Anti-clogging Regulatory Mechanisms of an Auto-flushing Emitter for Drip Irrigation under Sediment‑Laden Water Conditions

Zongze Yang, Baolin Yao, Yanqun Zhang, Yan Mo et al.
Research Square
Irrigation Practices and Water Management
preprint

Hydraulic Performance Variation and Anti-clogging Regulatory Mechanisms of an Auto-flushing Emitter for Drip Irrigation under Sediment‑Laden Water Conditions

Zongze Yang, Baolin Yao, Yanqun Zhang, Yan Mo, Sanmin Sun, Hao Gao, Hao Li, Qiameng Du
preprint en

Abstract

Emitter clogging severely limits drip irrigation using sediment-laden water. This study developed a novel auto-flushing emitter (AFE) with deformable elastomers, which switches between normal irrigation and auto‑flushing modes via pressure‑induced deformation that enlarges the flow cross‑section. Three emitter cores (EMI1, EMI2, EMI3) paired with three elastomers (silicone, SI; polyurethane, PU; non-deformable PTFE as the control, CK) were tested under clean water and sediment‑laden water (2 g/L, d50 = 34.84 µm). Under clean water, the AFE flow rate ( q CW ) increased stepwise with inlet pressure ( H 0 ), with an activation pressure threshold ( H j ) of 0.07–0.10 MPa. When H 0 > H j , q CW of the SI-fitted AFEs was 9.18–50.58% higher than that of the CKs. Under sediment‑laden water, the average relative discharge ( Dra ) of all nine emitters declined with operating time, but this decline weakened at higher H 0 and with softer elastomers. At 360 min, Dra of the SI-fitted AFEs exceeded PU-fitted and CKs by 14.2% and 30.2%, respectively. For AFEs, rising H 0 enlarged the flow cross-sectional area ( S ) and reduced mean flow velocity ( v ), whereas v increased in the CKs. Compared with PU-fitted AFEs and CKs, S of SI-fitted AFEs increased by 3.71–6.79% and 66.91–249.13%, respectively, and v (0.24–0.41 m/s) of the three SI-fitted AFEs overlapped the sediment incipient‑motion velocity (0.07–0.70 m/s). Correlation and regression analyses show that expanded S under auto-flushing is the primary driver of improved anti-clogging performance. These findings provide technical support for AFE development and sediment‑laden water drip‑irrigation application.

Research Square
Tarim University (CN), China Institute of Water Resources and Hydropower Research (CN)
Irrigation Practices and Water Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon