Robotic-Assisted Versus Conventional Pedicle Screw Fixation in Osteoporotic or Low-Bone-Mass Lumbar Degenerative Disease: A Systematic Review and Meta-Analysis of Screw Accuracy, Loosening, and Clinical Outcomes

Background Osteoporosis and low bone mass reduce the holding power of pedicle screws, increasing the risks of screw malposition, loosening, and revision surgery after lumbar fusion. Robot assistance may improve screw trajectory execution, but quantitative evidence specific to this population is currently lacking. Results This study ultimately included 8 studies comprising 554 patients. All studies were conducted in China, including 2 randomized controlled trials and 6 retrospective controlled studies. Six studies involving 1,731 screws reported that the acceptable placement rate was 777/818 (95.0%) in the robot group versus 771/913 (84.4%) in the conventional group. The random-effects risk ratio (RR) was 1.12 (95% CI 1.08–1.15, I² = 4.1%), with a Hartung-Knapp adjusted 95% CI of 1.08–1.16. Three studies showed less facet joint violation in the robot group (45/488 vs. 135/528; RR 0.36, adjusted 95% CI 0.14–0.94, I² = 45.8%). Three studies indicated that the robot group had an average reduction in intraoperative blood loss of approximately 47 mL (Hartung-Knapp 95% CI − 85 to − 8 mL, I² = 68.8%), though heterogeneity was high. Conclusion Although the robot-guided pedicle screw implantation technique holds promise in improving the accuracy of single-screw implantation and reducing interference with the facet joints in the treatment of lumbar degenerative diseases for patients with osteoporosis or low bone mass, current research data do not provide sufficient evidence to confirm that this technique can effectively prevent postoperative screw loosening or optimize patient-reported functional scores. Therefore, before establishing it as a routine clinical protocol, more long-term controlled studies with patients as the unit of observation are still needed.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-19
DOI
https://doi.org/10.21203/rs.3.rs-11659970/v1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Robotic-Assisted Versus Conventional Pedicle Screw Fixation in Osteoporotic or Low-Bone-Mass Lumbar Degenerative Disease: A Systematic Review and Meta-Analysis of Screw Accuracy, Loosening, and Clinical Outcomes

Guanjie Wei, Zeng Wang, Yucheng Wu, Heng-Zhi Guo et al.
Research Square
Spinal Fractures and Fixation Techniques
preprint

Robotic-Assisted Versus Conventional Pedicle Screw Fixation in Osteoporotic or Low-Bone-Mass Lumbar Degenerative Disease: A Systematic Review and Meta-Analysis of Screw Accuracy, Loosening, and Clinical Outcomes

Guanjie Wei, Zeng Wang, Yucheng Wu, Heng-Zhi Guo, Xiao-Bo Li, Pan Deng, Can Liu, De-Jian Xiang, Xiao-jun Huang, Dong Zhao
preprint en

Abstract

Background Osteoporosis and low bone mass reduce the holding power of pedicle screws, increasing the risks of screw malposition, loosening, and revision surgery after lumbar fusion. Robot assistance may improve screw trajectory execution, but quantitative evidence specific to this population is currently lacking. Results This study ultimately included 8 studies comprising 554 patients. All studies were conducted in China, including 2 randomized controlled trials and 6 retrospective controlled studies. Six studies involving 1,731 screws reported that the acceptable placement rate was 777/818 (95.0%) in the robot group versus 771/913 (84.4%) in the conventional group. The random-effects risk ratio (RR) was 1.12 (95% CI 1.08–1.15, I² = 4.1%), with a Hartung-Knapp adjusted 95% CI of 1.08–1.16. Three studies showed less facet joint violation in the robot group (45/488 vs. 135/528; RR 0.36, adjusted 95% CI 0.14–0.94, I² = 45.8%). Three studies indicated that the robot group had an average reduction in intraoperative blood loss of approximately 47 mL (Hartung-Knapp 95% CI − 85 to − 8 mL, I² = 68.8%), though heterogeneity was high. Conclusion Although the robot-guided pedicle screw implantation technique holds promise in improving the accuracy of single-screw implantation and reducing interference with the facet joints in the treatment of lumbar degenerative diseases for patients with osteoporosis or low bone mass, current research data do not provide sufficient evidence to confirm that this technique can effectively prevent postoperative screw loosening or optimize patient-reported functional scores. Therefore, before establishing it as a routine clinical protocol, more long-term controlled studies with patients as the unit of observation are still needed.

Research Square
The First People's Hospital of Guangyuan (CN)
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon