MXene@SiC Nanocomposite-Modified Electrode for Sensitive Electrochemical Detection of Cadmium (II) Ions

Cadmium (II) ions are highly toxic contaminants that can pose significant risks to environmental and human health, necessitating the development of sensitive and reliable analytical methods for their determination. In this study, an MXene@SiC nanocomposite-modified glassy carbon electrode (MXene@SiC/GCE) was developed for the electrochemical detection of Cd (II) ions. Carbon-based materials have been widely investigated for electrochemical sensing due to their high electrical conductivity, large specific surface area, and properties that enhance electron transfer. The MXene@SiC nanocomposite was prepared by combining Ti3C2Tx MXene and SiC at a 1:1 mass ratio. The structural and surface characteristics of the prepared materials were investigated by SEM, EDS, and FTIR analyses, confirming the successful integration of MXene and SiC. The electrochemical properties of the modified electrode were evaluated by cyclic voltammetry using the [Fe(CN)6]3−/[Fe(CN)6]4− redox probe. The effect of key experimental parameters, including scan rate, pH, accumulation time, and deposition potential, was investigated. The optimum conditions were found to be pH 5, an accumulation time of 350 s, and a deposition potential of −1.2 V. Under optimized conditions, the MXene@SiC/GCE exhibited a well-defined Cd(II) stripping response at approximately −0.9 V. Two linear concentration ranges were obtained: 0.5–1000 μg/L with the calibration equation I = 0.2932C + 1.5916 (R2 = 0.9893) and a higher concentration range with I = 0.04911C + 33.6442 (R2 = 0.9643). The developed electrode demonstrated a concentration-dependent response and satisfactory electrochemical characteristics, indicating that the MXene@SiC nanocomposite is a promising electrode-modifying material for Cd(II) determination in aqueous samples.

Authors

Institutions

Publication Details

Journal
C – Journal of Carbon Research
Published
2026-11-19
DOI
https://doi.org/10.3390/c12040090
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MXene@SiC Nanocomposite-Modified Electrode for Sensitive Electrochemical Detection of Cadmium (II) Ions

Zhazira Mukatayeva, 王立世, Yerbol Tileuberdi, Qiang Zeng et al.
C – Journal of Carbon Research
Electrochemical Analysis and Applications
article

MXene@SiC Nanocomposite-Modified Electrode for Sensitive Electrochemical Detection of Cadmium (II) Ions

Zhazira Mukatayeva, 王立世, Yerbol Tileuberdi, Qiang Zeng, Yrysgul Bakytkarim, Nurgul Shadin, Diana Konarbay, Nazira Sagatbekova
article en

Abstract

Cadmium (II) ions are highly toxic contaminants that can pose significant risks to environmental and human health, necessitating the development of sensitive and reliable analytical methods for their determination. In this study, an MXene@SiC nanocomposite-modified glassy carbon electrode (MXene@SiC/GCE) was developed for the electrochemical detection of Cd (II) ions. Carbon-based materials have been widely investigated for electrochemical sensing due to their high electrical conductivity, large specific surface area, and properties that enhance electron transfer. The MXene@SiC nanocomposite was prepared by combining Ti3C2Tx MXene and SiC at a 1:1 mass ratio. The structural and surface characteristics of the prepared materials were investigated by SEM, EDS, and FTIR analyses, confirming the successful integration of MXene and SiC. The electrochemical properties of the modified electrode were evaluated by cyclic voltammetry using the [Fe(CN)6]3−/[Fe(CN)6]4− redox probe. The effect of key experimental parameters, including scan rate, pH, accumulation time, and deposition potential, was investigated. The optimum conditions were found to be pH 5, an accumulation time of 350 s, and a deposition potential of −1.2 V. Under optimized conditions, the MXene@SiC/GCE exhibited a well-defined Cd(II) stripping response at approximately −0.9 V. Two linear concentration ranges were obtained: 0.5–1000 μg/L with the calibration equation I = 0.2932C + 1.5916 (R2 = 0.9893) and a higher concentration range with I = 0.04911C + 33.6442 (R2 = 0.9643). The developed electrode demonstrated a concentration-dependent response and satisfactory electrochemical characteristics, indicating that the MXene@SiC nanocomposite is a promising electrode-modifying material for Cd(II) determination in aqueous samples.

C – Journal of Carbon ResearchVol. 12(4)
Abai Kazakh National Pedagogical University (KZ), South China University of Technology (CN)
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon