Technical Pitfalls in Optic Nerve Sheath Diameter POCUS: A Practical Checklist for Image Optimization

Background: Point of care ultrasound (POCUS) measurement of the optic nerve sheath diameter (ONSD) has been established as a non-invasive method for estimating intracranial pressure in critically ill patients. However, the accuracy of the technique depends strongly on proper image acquisition. Errors in system optimization may result in inaccurate measurements and increased inter-operator variability. Objective: Our objective was to describe the most common technical errors in ONSD measurement and to propose a checklist to optimize image acquisition. Methods: A narrative review of the literature and an analysis of technical errors observed during POCUS training in critical care settings were completed. Emphasis was on ultrasound system parameters and image acquisition. Results: Six key technical elements were identified to optimize ONSD measurement. They included preset selection, depth adjustment, focal zone positioning, transducer frequency, gain optimization, and identification of the central retinal artery and vein. Conclusion: Standardization of ultrasound system settings may improve image quality and reduce measurement errors in ONSD, increasing reproducibility in emergency and critical care settings.

Authors

Institutions

Publication Details

Journal
POCUS Journal
Published
2026-11-18
DOI
https://doi.org/10.24908/pocusj.v11i02.20719
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Technical Pitfalls in Optic Nerve Sheath Diameter POCUS: A Practical Checklist for Image Optimization

Ricardo Bañuelos-Huerta, Wendy Sartillo Guerra, Eduardo Yahir Aguilar-Lazcano, Montserrat Ramírez-Barranco et al.
POCUS Journal
Ultrasound in Clinical Applications
article

Technical Pitfalls in Optic Nerve Sheath Diameter POCUS: A Practical Checklist for Image Optimization

Ricardo Bañuelos-Huerta, Wendy Sartillo Guerra, Eduardo Yahir Aguilar-Lazcano, Montserrat Ramírez-Barranco, Gilver Sebastián-Vázquez, Wendy J. Ramírez-Salvador, Jorge A. Lara-Arellano, Carlos Estrada-Valencia, Dibanhi S. Ruvalcaba-Trujillo, Daniel de J. Vázquez-Hernández
article en

Abstract

Background: Point of care ultrasound (POCUS) measurement of the optic nerve sheath diameter (ONSD) has been established as a non-invasive method for estimating intracranial pressure in critically ill patients. However, the accuracy of the technique depends strongly on proper image acquisition. Errors in system optimization may result in inaccurate measurements and increased inter-operator variability. Objective: Our objective was to describe the most common technical errors in ONSD measurement and to propose a checklist to optimize image acquisition. Methods: A narrative review of the literature and an analysis of technical errors observed during POCUS training in critical care settings were completed. Emphasis was on ultrasound system parameters and image acquisition. Results: Six key technical elements were identified to optimize ONSD measurement. They included preset selection, depth adjustment, focal zone positioning, transducer frequency, gain optimization, and identification of the central retinal artery and vein. Conclusion: Standardization of ultrasound system settings may improve image quality and reduce measurement errors in ONSD, increasing reproducibility in emergency and critical care settings.

POCUS JournalVol. 11(02)
Universidad Autónoma de Tlaxcala (MX), Mexican Social Security Institute (MX), Hospital General De Zona (MX), Institute for Social Security and Services for State Workers (MX)
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon