Radiation dose and institutional diagnostic reference level for CT pulmonary angiography among pregnant women: A single-centre study

Background CT pulmonary angiography (CTPA) is commonly used to investigate suspected pulmonary embolism (PE) during pregnancy, but institutional radiation-dose benchmarks are limited. This study evaluated CTPA dose metrics and proposed institutional diagnostic reference levels (IDRLs) in pregnant patients. Methods This retrospective single-centre study included 120 consecutive pregnant patients who underwent CTPA for suspected PE over a 10-year period (from October 2016 to March 2026). CTDIvol and dose–length product (DLP) were reported. IDRLs were defined as the 75th percentiles of dose distributions. Effective dose was estimated as DLP × 0.014 mSv·mGy −1 ·cm −1 . Nonparametric analyses evaluated associations with patient, acquisition, trimester, and temporal variables. Results Mean maternal age was 33.53 ± 6.78 years. Six examinations (5.0%) were positive for PE. Mean CTDIvol and DLP were 12.15 ± 4.30 mGy and 307.89 ± 123.89 mGy·cm, respectively, corresponding to an estimated effective dose of 4.31 ± 1.73 mSv. The proposed IDRLs were 14.43 mGy for CTDIvol and 357.36 mGy·cm for DLP. BMI was positively correlated with CTDIvol ( r s = 0.447 , p < 0.001) and DLP ( r s = 0.395 , p < 0.001); scan length showed the strongest association with DLP ( r s = 0.464 , p < 0.001). No significant differences in dose metrics were identified across gestational trimesters or study periods. Reference values from the 2023–2026 cohort were similar to those from the full cohort. Conclusion This study proposed IDRLs for CTPA in pregnant patients in Saudi Arabia. The findings provide local benchmarks for dose monitoring, protocol review, and future multicentre development of pregnancy-specific reference levels.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2026-11-19
DOI
https://doi.org/10.1016/j.jrras.2026.102846
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Radiation dose and institutional diagnostic reference level for CT pulmonary angiography among pregnant women: A single-centre study

Salman Mohammed Albeshan, Ahmed Alanazi, Sultan Bakhit Alghamdi, Mohammed Ibrahim Almasoud
Journal of Radiation Research and Applied Sciences
Radiation Dose and Imaging
article

Radiation dose and institutional diagnostic reference level for CT pulmonary angiography among pregnant women: A single-centre study

Salman Mohammed Albeshan, Ahmed Alanazi, Sultan Bakhit Alghamdi, Mohammed Ibrahim Almasoud
article en

Abstract

Background CT pulmonary angiography (CTPA) is commonly used to investigate suspected pulmonary embolism (PE) during pregnancy, but institutional radiation-dose benchmarks are limited. This study evaluated CTPA dose metrics and proposed institutional diagnostic reference levels (IDRLs) in pregnant patients. Methods This retrospective single-centre study included 120 consecutive pregnant patients who underwent CTPA for suspected PE over a 10-year period (from October 2016 to March 2026). CTDIvol and dose–length product (DLP) were reported. IDRLs were defined as the 75th percentiles of dose distributions. Effective dose was estimated as DLP × 0.014 mSv·mGy −1 ·cm −1 . Nonparametric analyses evaluated associations with patient, acquisition, trimester, and temporal variables. Results Mean maternal age was 33.53 ± 6.78 years. Six examinations (5.0%) were positive for PE. Mean CTDIvol and DLP were 12.15 ± 4.30 mGy and 307.89 ± 123.89 mGy·cm, respectively, corresponding to an estimated effective dose of 4.31 ± 1.73 mSv. The proposed IDRLs were 14.43 mGy for CTDIvol and 357.36 mGy·cm for DLP. BMI was positively correlated with CTDIvol ( r s = 0.447 , p < 0.001) and DLP ( r s = 0.395 , p < 0.001); scan length showed the strongest association with DLP ( r s = 0.464 , p < 0.001). No significant differences in dose metrics were identified across gestational trimesters or study periods. Reference values from the 2023–2026 cohort were similar to those from the full cohort. Conclusion This study proposed IDRLs for CTPA in pregnant patients in Saudi Arabia. The findings provide local benchmarks for dose monitoring, protocol review, and future multicentre development of pregnancy-specific reference levels.

Journal of Radiation Research and Applied SciencesVol. 19(4)
King Saud University (SA), Security Forces Hospital (SA)
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon