Covalently anchored layer-by-layer minocycline-loaded chitosan/alginate coating on titanium sustains minocycline release while preserving osteoblast compatibility

Objective Peri-implantitis, driven by bacterial biofilm formation, remains a major cause of late implant failure. We developed a covalently anchored coating to prolong local minocycline release from titanium implants and evaluated its ability to prevent Staphylococcus aureus colonization and subsequent biofilm formation, and its compatibility with osteoblast-like cells. Methods A minocycline (Mino)-loaded chitosan (Chi)/alginate (Alg) multilayer film was fabricated using a modified layer-by-layer (LbL) technique. The first Chi layer was covalently anchored onto hydroxylated Ti via (3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde (GA) crosslinking, followed by electrostatic assembly of (Chi/Alg) 5 multilayers. Mino was subsequently loaded into the film. Physicochemical properties were characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). In vitro minocycline release was monitored. Antibacterial efficacy against Staphylococcus aureus was evaluated over 14 days, while in vitro minocycline release was monitored for 30 days. Biocompatibility was assessed using MG63 osteoblast-like cells. Results A porous and highly hydrophilic coating was successfully constructed. Minocycline release sustained for 30 days, with the released concentration remaining above the MIC (4 μg/mL; mean 18.00 ± 1.73 μg/mL at Day 30). During the 14-day antibacterial evaluation, the coating reduced planktonic and adherent Staphylococcus aureus colonization by more than 80%. Cell viability remained above 85%, exceeding that of uncoated titanium. Conclusion This titanium-anchored LbL coating, covalently attached via the innermost Chi layer, exhibited sustained minocycline release and cytocompatibility in in-vitro assays, offering a promising surface-modification strategy that warrants further investigation toward clinical peri-implantitis management.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-11-19
DOI
https://doi.org/10.3389/fbioe.2026.1974166
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Covalently anchored layer-by-layer minocycline-loaded chitosan/alginate coating on titanium sustains minocycline release while preserving osteoblast compatibility

Zhang Xu, Jiang Hao, Zhang Zhenfang, Zhang Shuai et al.
Frontiers in Bioengineering and Biotechnology
Dental Implant Techniques and Outcomes
article

Covalently anchored layer-by-layer minocycline-loaded chitosan/alginate coating on titanium sustains minocycline release while preserving osteoblast compatibility

Zhang Xu, Jiang Hao, Zhang Zhenfang, Zhang Shuai, Li Zhangyi, Lv Hongbin
article en

Abstract

Objective Peri-implantitis, driven by bacterial biofilm formation, remains a major cause of late implant failure. We developed a covalently anchored coating to prolong local minocycline release from titanium implants and evaluated its ability to prevent Staphylococcus aureus colonization and subsequent biofilm formation, and its compatibility with osteoblast-like cells. Methods A minocycline (Mino)-loaded chitosan (Chi)/alginate (Alg) multilayer film was fabricated using a modified layer-by-layer (LbL) technique. The first Chi layer was covalently anchored onto hydroxylated Ti via (3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde (GA) crosslinking, followed by electrostatic assembly of (Chi/Alg) 5 multilayers. Mino was subsequently loaded into the film. Physicochemical properties were characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). In vitro minocycline release was monitored. Antibacterial efficacy against Staphylococcus aureus was evaluated over 14 days, while in vitro minocycline release was monitored for 30 days. Biocompatibility was assessed using MG63 osteoblast-like cells. Results A porous and highly hydrophilic coating was successfully constructed. Minocycline release sustained for 30 days, with the released concentration remaining above the MIC (4 μg/mL; mean 18.00 ± 1.73 μg/mL at Day 30). During the 14-day antibacterial evaluation, the coating reduced planktonic and adherent Staphylococcus aureus colonization by more than 80%. Cell viability remained above 85%, exceeding that of uncoated titanium. Conclusion This titanium-anchored LbL coating, covalently attached via the innermost Chi layer, exhibited sustained minocycline release and cytocompatibility in in-vitro assays, offering a promising surface-modification strategy that warrants further investigation toward clinical peri-implantitis management.

Frontiers in Bioengineering and BiotechnologyVol. 14
Fifth Tianjin Central Hospital (CN), Tianjin Medical University (CN)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon