Towards an understanding of injury in aortic tissue prior to actual failure: quantification of mechanically induced collagen damage using collagen hybridizing peptides

The development, validation, and optimization of endovascular aortic devices require quantitative assessment of tissue damage occurring during surgical interventions. Until now, this assessment—before complete failure—has been largely unfeasible for lack of a suitable methodology. Recently developed collagen hybridizing peptides (CHPs) allow selective detection of damage to collagen, the primary load-bearing constituent of the aortic wall. However, their application in large, mechanically loaded arteries has not yet been established. Therefore, we optimized an experimental workflow for large arteries that accounts for their energy-storage function and geometrical constraints; furthermore, we have characterized the tissue's autofluorescence and selected a suitable CHP fluorophore. Specimens from a single porcine aorta were examined using uniaxial tensile testing, histological analysis, fluorescence spectral analysis, confocal microscopy, and quantitative image analysis to present collagen damage as a function of tissue stretch. The workflow detected load-induced collagen damage before tissue failure, whereas histological evaluation showed no obvious load-induced disruption. Damage scores were comparable between the undeformed control and the specimen stretched by a factor of 1.2, while specimens stretched beyond 1.2 exhibited elevated scores. This pattern corresponded to higher complication rates with excessive stent oversizing. Furthermore, the proposed protocol can be adapted for ex vivo stent deployment experiments to compare collagen damage resulting from various aortic device designs and deployment conditions. Quantitative damage metrics could inform structurally motivated constitutive material models for computational simulations of endovascular interventions. Combined with histological and structural analyses, this workflow could also help link tissue composition—or organization—to individual susceptibility to damage.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-19
DOI
https://doi.org/10.64898/2026.11.18.767693
Primary Topic
Elasticity and Material Modeling
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Towards an understanding of injury in aortic tissue prior to actual failure: quantification of mechanically induced collagen damage using collagen hybridizing peptides

Gerhard A. Holzapfel, Daniel Ch. Haspinger, Heimo Wolinski, Janna C. Nawroth et al.
bioRxiv (Cold Spring Harbor Laboratory)
Elasticity and Material Modeling
preprint

Towards an understanding of injury in aortic tissue prior to actual failure: quantification of mechanically induced collagen damage using collagen hybridizing peptides

Gerhard A. Holzapfel, Daniel Ch. Haspinger, Heimo Wolinski, Janna C. Nawroth, Christian Viertler, Anna Pukaluk
preprint en

Abstract

The development, validation, and optimization of endovascular aortic devices require quantitative assessment of tissue damage occurring during surgical interventions. Until now, this assessment—before complete failure—has been largely unfeasible for lack of a suitable methodology. Recently developed collagen hybridizing peptides (CHPs) allow selective detection of damage to collagen, the primary load-bearing constituent of the aortic wall. However, their application in large, mechanically loaded arteries has not yet been established. Therefore, we optimized an experimental workflow for large arteries that accounts for their energy-storage function and geometrical constraints; furthermore, we have characterized the tissue's autofluorescence and selected a suitable CHP fluorophore. Specimens from a single porcine aorta were examined using uniaxial tensile testing, histological analysis, fluorescence spectral analysis, confocal microscopy, and quantitative image analysis to present collagen damage as a function of tissue stretch. The workflow detected load-induced collagen damage before tissue failure, whereas histological evaluation showed no obvious load-induced disruption. Damage scores were comparable between the undeformed control and the specimen stretched by a factor of 1.2, while specimens stretched beyond 1.2 exhibited elevated scores. This pattern corresponded to higher complication rates with excessive stent oversizing. Furthermore, the proposed protocol can be adapted for ex vivo stent deployment experiments to compare collagen damage resulting from various aortic device designs and deployment conditions. Quantitative damage metrics could inform structurally motivated constitutive material models for computational simulations of endovascular interventions. Combined with histological and structural analyses, this workflow could also help link tissue composition—or organization—to individual susceptibility to damage.

bioRxiv (Cold Spring Harbor Laboratory)
University of Graz (AT), Medical University of Graz (AT), Helmholtz Zentrum München (DE), Graz University of Technology (AT)
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon