Redundant Links Are Not Series Elements: Fault-Injection Evidence from ROS 2 Control Architectures

Reliability models can misrepresent redundant paths when communication links are treated as series elements. We tested this assumption through accelerated process-level fault injection in six running ROS 2 control architectures, comparing precomputed continuous-time Markov predictions based on graph logic (A) and a series-link rule (B). A pilot recorded 360 system failures; separate protocol-frozen studies recorded 960 signal-level failures, 400 trials with imposed common-cause failures and 540 trials with message loss, alongside 131 selected production windows from six simulated cells. No model parameter was fitted to observed failure times. In the two architectures that discriminate between A and B, the series-link model underestimated the observed mean time to signal loss by 44–52% and fell outside the prespecified confidence intervals. It also underestimated production in selected windows by 14–19%, although formal inference varied with the interval method and incident accounting. Model A met the prespecified agreement rule in five of six architectures at signal level; its production-rate errors were 1.7–3.8% under the prespecified summary, with sensitivity to window dependence. A statistically established advantage of parallel over single links was not obtained (difference 4.0 s, 95% CI −1.1 to 9.2). Under imposed common-cause failures, an independence model overestimated mean time to loss by up to 65%, while an injector-matched common-cause extension stayed within 9%. Agreement deteriorated under severe message loss. The findings support a falsification-oriented test of architecture-level reliability assumptions in running middleware, not claims about hardware failure rates or universal robotic reliability.

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-18
DOI
https://doi.org/10.20944/preprints202611.1940.v1
Primary Topic
Reliability and Maintenance Optimization
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Redundant Links Are Not Series Elements: Fault-Injection Evidence from ROS 2 Control Architectures

Mauricio Holguín Londoño, Germán Andrés Holguín Londoño, Daniela Buitrago Largo, Kevin David Ortega Quiñones et al.
Preprints.org
Reliability and Maintenance Optimization
preprint

Redundant Links Are Not Series Elements: Fault-Injection Evidence from ROS 2 Control Architectures

Mauricio Holguín Londoño, Germán Andrés Holguín Londoño, Daniela Buitrago Largo, Kevin David Ortega Quiñones, Andrés Escobar Mejía
preprint en

Abstract

Reliability models can misrepresent redundant paths when communication links are treated as series elements. We tested this assumption through accelerated process-level fault injection in six running ROS 2 control architectures, comparing precomputed continuous-time Markov predictions based on graph logic (A) and a series-link rule (B). A pilot recorded 360 system failures; separate protocol-frozen studies recorded 960 signal-level failures, 400 trials with imposed common-cause failures and 540 trials with message loss, alongside 131 selected production windows from six simulated cells. No model parameter was fitted to observed failure times. In the two architectures that discriminate between A and B, the series-link model underestimated the observed mean time to signal loss by 44–52% and fell outside the prespecified confidence intervals. It also underestimated production in selected windows by 14–19%, although formal inference varied with the interval method and incident accounting. Model A met the prespecified agreement rule in five of six architectures at signal level; its production-rate errors were 1.7–3.8% under the prespecified summary, with sensitivity to window dependence. A statistically established advantage of parallel over single links was not obtained (difference 4.0 s, 95% CI −1.1 to 9.2). Under imposed common-cause failures, an independence model overestimated mean time to loss by up to 65%, while an injector-matched common-cause extension stayed within 9%. Agreement deteriorated under severe message loss. The findings support a falsification-oriented test of architecture-level reliability assumptions in running middleware, not claims about hardware failure rates or universal robotic reliability.

Preprints.org
Reliability and Maintenance Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon