Comparative performance of GEOPOLYMER reinforced concrete beams

This research investigated the response of geopolymer reinforced concrete beams considering different span lengths, cross-sectional dimensions, and longitudinal reinforcement. A total of seven beams, designated D1–D7, were tested, with beam lengths ranging from 450 to 600 mm and depths from 150 to 450 mm. The compressive strength of the geopolymer concrete was 25.9 MPa, achieved under ambient curing conditions. All beams were also ambient cured and subsequently tested under three-point bending, exhibiting peak loads between 53.80 and 236.70 kN. With shear-span-to-beam-depth ratios (a/h) varying from 0.33 to 1.50, the tested beams exhibited predominantly shear-controlled behavior, characterized by diagonal cracking and shear-dominated failure. The experimental results were also compared with analytical predictions to evaluate the applicability of existing design approaches to the tested geopolymer concrete beams. The use of geopolymer concrete without heat curing eliminates the need for an additional heat-curing process and may facilitate practical on-site casting.

Authors

Institutions

Publication Details

Journal
Australian Journal of Civil Engineering
Published
2026-11-19
DOI
https://doi.org/10.1080/14488353.2026.2756033
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative performance of GEOPOLYMER reinforced concrete beams

Duy‐Liem Nguyen, Duc-Hung Phan
Australian Journal of Civil Engineering
Structural Behavior of Reinforced Concrete
article

Comparative performance of GEOPOLYMER reinforced concrete beams

Duy‐Liem Nguyen, Duc-Hung Phan
article en

Abstract

This research investigated the response of geopolymer reinforced concrete beams considering different span lengths, cross-sectional dimensions, and longitudinal reinforcement. A total of seven beams, designated D1–D7, were tested, with beam lengths ranging from 450 to 600 mm and depths from 150 to 450 mm. The compressive strength of the geopolymer concrete was 25.9 MPa, achieved under ambient curing conditions. All beams were also ambient cured and subsequently tested under three-point bending, exhibiting peak loads between 53.80 and 236.70 kN. With shear-span-to-beam-depth ratios (a/h) varying from 0.33 to 1.50, the tested beams exhibited predominantly shear-controlled behavior, characterized by diagonal cracking and shear-dominated failure. The experimental results were also compared with analytical predictions to evaluate the applicability of existing design approaches to the tested geopolymer concrete beams. The use of geopolymer concrete without heat curing eliminates the need for an additional heat-curing process and may facilitate practical on-site casting.

Australian Journal of Civil Engineering
Ho Chi Minh City University of Technology and Engineering (VN)
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon