Physics-informed hybrid soft sensing and distribution-constrained tandem inverse design for partially observed industrial emission abatement
Industrial emission abatement is partially observed: only the stack concentration is measured, whereas pollutant generation and removal efficiency are not. We develop a hybrid soft sensor and a distribution-constrained tandem inverse design and test which of their outputs the data support. On daily data from five sintering units, the test 𝑅 2 of the NO x sensor fell from 0.68 under a random split to 0.18–0.35 under leakage-controlled splits, and SO x was not predictable out of period. The level of the inferred efficiency was not identified, because a ± 20 % bias in the white-box term left accuracy unchanged, but its day-to-day changes were largely identified and tracked the selective catalytic reduction (SCR) inlet temperature, a variable outside the model. For inverse design, self-reconstruction and cross-surrogate 𝑅 2 ranked generated conditions above real ones, whereas realism and coverage metrics reversed this ranking. Prediction intervals lost coverage near the limit under period shift.
Authors
- Jaerak Ko (ORCID: https://orcid.org/0009-0001-5178-9078)
- Soonho Hwangbo (ORCID: https://orcid.org/0000-0003-2208-9301)
- Eonjun Choi
- Weejin Lee
- Chanho Kim (ORCID: https://orcid.org/0009-0003-4450-8973)
Institutions
- Gyeongsang National University (KR)
Publication Details
- Journal
- Ain Shams Engineering Journal
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1016/j.asej.2026.104539
- Primary Topic
- Fault Detection and Control Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00