Impact of Fine Recycled Mortar Aggregates on Hydration, Microstructure, and Performance of Cementitious Materials

Fine recycled mortar aggregate (FRMA) is a promising secondary raw material for cementitious composites. However, its residual porosity, high fines content, and increased water demand can adversely affect hydration and engineering performance. This study investigated the influence of FRMA through two complementary experimental series. First, Portland cement–FRMA systems containing 0–100 wt.% FRMA were evaluated by calorimetry to characterize early-age heat evolution. Second, natural sand was replaced with 10–50 wt.% FRMA in polymer- and superplasticizer-modified mortars. The mortars were assessed in terms of flowability, density, ultrasonic pulse velocity (UPV), compressive and flexural strength, and characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Increasing the FRMA content progressively delayed the main hydration peak and reduced cumulative heat release. The second heat-flow maximum shifted from 13.0 h for the reference paste to 17.1 h at 50% replacement, while the 48 h relative cumulative heat index decreased to 71.9%. Mortar flowability decreased by up to 12%, from 125 to 110 mm. Moderate FRMA replacement levels of 10–20% preserved density and UPV and maintained or slightly improved compressive strength. The highest 28-day compressive strength, 62.9 MPa, was obtained at 20% FRMA, approximately 3.9% above the reference value. At 30–50% replacement, density, UPV, and compressive strength decreased as the effects of porous residual mortar, higher water demand, and a higher water-to-cement ratio (W/C) became more pronounced. SEM observations confirmed greater microstructural heterogeneity at higher FRMA contents, whereas XRD showed broadly similar crystalline hydration products in all mortars. Overall, FRMA replacement levels of 10–20% provided the most favorable balance between recycled-material utilization and mortar performance in the investigated mixture design.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-19
DOI
https://doi.org/10.3390/app162211475
Primary Topic
Recycled Aggregate Concrete Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Impact of Fine Recycled Mortar Aggregates on Hydration, Microstructure, and Performance of Cementitious Materials

Renata Boris, Aigerim K. Tolegenova, Yahor Trambitski, Remigijus Šalna et al.
Applied Sciences
Recycled Aggregate Concrete Performance
article

Impact of Fine Recycled Mortar Aggregates on Hydration, Microstructure, and Performance of Cementitious Materials

Renata Boris, Aigerim K. Tolegenova, Yahor Trambitski, Remigijus Šalna, Liudmyla Rishko
article en

Abstract

Fine recycled mortar aggregate (FRMA) is a promising secondary raw material for cementitious composites. However, its residual porosity, high fines content, and increased water demand can adversely affect hydration and engineering performance. This study investigated the influence of FRMA through two complementary experimental series. First, Portland cement–FRMA systems containing 0–100 wt.% FRMA were evaluated by calorimetry to characterize early-age heat evolution. Second, natural sand was replaced with 10–50 wt.% FRMA in polymer- and superplasticizer-modified mortars. The mortars were assessed in terms of flowability, density, ultrasonic pulse velocity (UPV), compressive and flexural strength, and characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Increasing the FRMA content progressively delayed the main hydration peak and reduced cumulative heat release. The second heat-flow maximum shifted from 13.0 h for the reference paste to 17.1 h at 50% replacement, while the 48 h relative cumulative heat index decreased to 71.9%. Mortar flowability decreased by up to 12%, from 125 to 110 mm. Moderate FRMA replacement levels of 10–20% preserved density and UPV and maintained or slightly improved compressive strength. The highest 28-day compressive strength, 62.9 MPa, was obtained at 20% FRMA, approximately 3.9% above the reference value. At 30–50% replacement, density, UPV, and compressive strength decreased as the effects of porous residual mortar, higher water demand, and a higher water-to-cement ratio (W/C) became more pronounced. SEM observations confirmed greater microstructural heterogeneity at higher FRMA contents, whereas XRD showed broadly similar crystalline hydration products in all mortars. Overall, FRMA replacement levels of 10–20% provided the most favorable balance between recycled-material utilization and mortar performance in the investigated mixture design.

Applied SciencesVol. 16(22)
Vilnius Gediminas Technical University (LT), Satbayev University (KZ)
Recycled Aggregate Concrete Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon