Percutaneous Management of a Retained Coronary Snare Fragment: Retrieval-Related Side-Branch Perforation and Migration to the External Iliac Artery: A Case Report

Background Retained or fractured intracoronary devices are uncommon but potentially serious complications of complex percutaneous coronary intervention. Retrieval may itself cause vascular injury or systemic embolization and can require several bailout techniques. Case presentation: A 50-year-old man was referred after a chronic total occlusion intervention at another institution had been complicated by guidewire fracture and subsequent fracture of the snare used for retrieval. The retained snare fragment extended from the right coronary artery toward the aorta. Repeat snaring and a three-wire knot technique were unsuccessful. Balloon-assisted retrieval mobilized the fragment but caused disengagement of the system; the fragment escaped into the systemic circulation and was localized to the right external iliac artery. Control coronary angiography demonstrated perforation of the side branch used for balloon anchoring. Extravasation persisted despite prolonged balloon inflation, and microcatheter delivery for coil embolization was unsuccessful. The perforated branch was therefore occluded with a cut balloon. After angiographic hemostasis, the embolized snare fragment was captured with a peripheral snare and removed through the sheath. The patient remained hemodynamically stable, developed no tamponade, and had no procedure-related complication at 3 months. Conclusion This case illustrates a stepwise percutaneous strategy for a cascade of device-related complications. Maintaining control of the foreign body, rapidly reassessing the coronary circulation after device migration, prioritizing active coronary perforation, and retaining alternative embolization options when microcatheter delivery fails were central to successful management.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-20
DOI
https://doi.org/10.21203/rs.3.rs-11433933/v1
Primary Topic
Coronary Interventions and Diagnostics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Percutaneous Management of a Retained Coronary Snare Fragment: Retrieval-Related Side-Branch Perforation and Migration to the External Iliac Artery: A Case Report

Ali Yaşar Kılınç, Mucteba Talha Aydin
Research Square
Coronary Interventions and Diagnostics
preprint

Percutaneous Management of a Retained Coronary Snare Fragment: Retrieval-Related Side-Branch Perforation and Migration to the External Iliac Artery: A Case Report

Ali Yaşar Kılınç, Mucteba Talha Aydin
preprint en

Abstract

Background Retained or fractured intracoronary devices are uncommon but potentially serious complications of complex percutaneous coronary intervention. Retrieval may itself cause vascular injury or systemic embolization and can require several bailout techniques. Case presentation: A 50-year-old man was referred after a chronic total occlusion intervention at another institution had been complicated by guidewire fracture and subsequent fracture of the snare used for retrieval. The retained snare fragment extended from the right coronary artery toward the aorta. Repeat snaring and a three-wire knot technique were unsuccessful. Balloon-assisted retrieval mobilized the fragment but caused disengagement of the system; the fragment escaped into the systemic circulation and was localized to the right external iliac artery. Control coronary angiography demonstrated perforation of the side branch used for balloon anchoring. Extravasation persisted despite prolonged balloon inflation, and microcatheter delivery for coil embolization was unsuccessful. The perforated branch was therefore occluded with a cut balloon. After angiographic hemostasis, the embolized snare fragment was captured with a peripheral snare and removed through the sheath. The patient remained hemodynamically stable, developed no tamponade, and had no procedure-related complication at 3 months. Conclusion This case illustrates a stepwise percutaneous strategy for a cascade of device-related complications. Maintaining control of the foreign body, rapidly reassessing the coronary circulation after device migration, prioritizing active coronary perforation, and retaining alternative embolization options when microcatheter delivery fails were central to successful management.

Research Square
Haseki Eğitim ve Araştırma Hastanesi (TR)
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon