The “Double-Hybrid” Strategy for Complex Primary Total Knee Arthroplasty Using a Varus–Valgus Constrained Insert and Standard Cementless Femoral Component

Background Varus–valgus constrained (VVC) inserts are increasingly used in complex primary total knee arthroplasty (TKA) when additional coronal plane stability is required. Because increased constraint increases mechanical stress, VVC constructs are traditionally combined with cemented stemmed femoral and tibial components. In parallel, cementless fixation in primary TKA has shown excellent survivorship and osseointegration. A construct combining a cementless posterior-stabilized (PS) femoral component with a cemented stemmed VVC tibial construct may enhance stability while preserving bone stock. Outcomes of this "double-hybrid" strategy remain unreported. Methods We retrospectively reviewed 45 complex primary TKAs in 40 patients at a single institution (2021-2025). Mean age was 64.9 ± 13.0 years, and median body mass index (BMI) was 30.6 kg/m 2 (interquartile range (IQR) 26.1-32.9). All procedures used a medial parapatellar approach, mechanical alignment, and the same implant combination: cementless PS femoral component with cemented tibial Universal Baseplate, short stem, and VVC insert. Outcomes included radiolucencies, aseptic loosening, instability or revision. Results At a median follow-up of 27 months (IQR 23-46), no mechanical failures, radiolucencies, or aseptic loosening occurred. Functional outcomes and patient-reported outcome measures improved significantly. HKA alignment improved significantly in both varus and valgus knees. No instability or revision occurred. Conclusions This "double-hybrid" construct demonstrated favorable short-term outcomes in complex primary TKA. The combination of a cementless PS femoral component with a cemented stemmed VVC tibial construct provided reliable stability without early failure or loosening. It may represent a bone-preserving option when increased constraint is required. Longer-term follow-up is needed to confirm durability.

Authors

Institutions

Publication Details

Journal
Arthroplasty Today
Published
2026-11-19
DOI
https://doi.org/10.1016/j.artd.2026.102210
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The “Double-Hybrid” Strategy for Complex Primary Total Knee Arthroplasty Using a Varus–Valgus Constrained Insert and Standard Cementless Femoral Component

Jaad Mahlouly, Alexander Antoniadis, Julien Wegrzyn, Anna Michel
Arthroplasty Today
Total Knee Arthroplasty Outcomes
article

The “Double-Hybrid” Strategy for Complex Primary Total Knee Arthroplasty Using a Varus–Valgus Constrained Insert and Standard Cementless Femoral Component

Jaad Mahlouly, Alexander Antoniadis, Julien Wegrzyn, Anna Michel
article en

Abstract

Background Varus–valgus constrained (VVC) inserts are increasingly used in complex primary total knee arthroplasty (TKA) when additional coronal plane stability is required. Because increased constraint increases mechanical stress, VVC constructs are traditionally combined with cemented stemmed femoral and tibial components. In parallel, cementless fixation in primary TKA has shown excellent survivorship and osseointegration. A construct combining a cementless posterior-stabilized (PS) femoral component with a cemented stemmed VVC tibial construct may enhance stability while preserving bone stock. Outcomes of this "double-hybrid" strategy remain unreported. Methods We retrospectively reviewed 45 complex primary TKAs in 40 patients at a single institution (2021-2025). Mean age was 64.9 ± 13.0 years, and median body mass index (BMI) was 30.6 kg/m 2 (interquartile range (IQR) 26.1-32.9). All procedures used a medial parapatellar approach, mechanical alignment, and the same implant combination: cementless PS femoral component with cemented tibial Universal Baseplate, short stem, and VVC insert. Outcomes included radiolucencies, aseptic loosening, instability or revision. Results At a median follow-up of 27 months (IQR 23-46), no mechanical failures, radiolucencies, or aseptic loosening occurred. Functional outcomes and patient-reported outcome measures improved significantly. HKA alignment improved significantly in both varus and valgus knees. No instability or revision occurred. Conclusions This "double-hybrid" construct demonstrated favorable short-term outcomes in complex primary TKA. The combination of a cementless PS femoral component with a cemented stemmed VVC tibial construct provided reliable stability without early failure or loosening. It may represent a bone-preserving option when increased constraint is required. Longer-term follow-up is needed to confirm durability.

Arthroplasty TodayVol. 42
Centre Hospitalier Universitaire Vaudois (CH), University of Lausanne (CH)
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon