Multi-beam FLASH-RT preserves skin sparing and reveals novel tissue oxygen dynamics in a murine model

Objective. The goal of this project was to investigate whether the FLASH skin-sparing effect is preserved across multi-beam ultra-high-dose-rate (UHDR) deliveries and to characterize the accompanying in vivo tissue oxygen dynamics near a 5-second total treatment window previously shown to maintain sparing. Approach. Mice were irradiated at three dose levels (23.6, 25.2, and 25.9 Gy) across five experimental groups: single-beam UHDR, two-beam UHDR, six beam UHDR, twelve-beam UHDR, and conventional dose rate (CDR). To evaluate normal tissue toxicity, a skin damage cohort was monitored photographically for four weeks post-irradiation, with acute reactions evaluated by a trained observer. In a separate cohort, real-time tissue oxygenation (pO2) was tracked via a fiber-optic phosphorometer using the phosphorescent probe Oxyphor PtG4 to evaluate physiological kinetics independently of the longitudinal toxicity study. Main results. The FLASH skin-sparing effect was statistically indistinguishable for all experimentally tested UHDR configurations at the 23.6 Gy and 25.2 Gy dose levels. Mixed-effects regression analysis demonstrated that all four UHDR groups developed significantly lower skin toxicity scores compared to the CDR group (p < 0.05). At the highest dose level (25.9 Gy), no significant differences were observed among any radiation groups, which was attributed to a saturation effect of the visual skin score assay at severe damage thresholds. In vivo oximetry showed that tissue oxygen resupply accelerated during UHDR treatment, driven by localized concentration gradients and amplified post-RT by acute biological mechanisms. Significance. This study represents a promising step toward UHDR multi-beam delivery, a prerequisite for clinical conformal treatment planning. Multiple UHDR beams delivered within five seconds provide a statistically indistinguishable degree of normal tissue sparing as a single UHDR beam. Furthermore, the observed tissue oxygen dynamics reveal an acute biological response potentially unique to UHDR delivery, shedding light on a novel physiological component of the FLASH mechanism.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-19
DOI
https://doi.org/10.1088/1361-6560/aec4b7
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-beam FLASH-RT preserves skin sparing and reveals novel tissue oxygen dynamics in a murine model

David I. Hunter, Petr Brůža, Aleksandra Ilina, David J. Gladstone et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Multi-beam FLASH-RT preserves skin sparing and reveals novel tissue oxygen dynamics in a murine model

David I. Hunter, Petr Brůža, Aleksandra Ilina, David J. Gladstone, Jason R. Gunn, Corbin Narita, Xu Cao, Kevin J. Willy, Brian W. Pogue
article en

Abstract

Objective. The goal of this project was to investigate whether the FLASH skin-sparing effect is preserved across multi-beam ultra-high-dose-rate (UHDR) deliveries and to characterize the accompanying in vivo tissue oxygen dynamics near a 5-second total treatment window previously shown to maintain sparing. Approach. Mice were irradiated at three dose levels (23.6, 25.2, and 25.9 Gy) across five experimental groups: single-beam UHDR, two-beam UHDR, six beam UHDR, twelve-beam UHDR, and conventional dose rate (CDR). To evaluate normal tissue toxicity, a skin damage cohort was monitored photographically for four weeks post-irradiation, with acute reactions evaluated by a trained observer. In a separate cohort, real-time tissue oxygenation (pO2) was tracked via a fiber-optic phosphorometer using the phosphorescent probe Oxyphor PtG4 to evaluate physiological kinetics independently of the longitudinal toxicity study. Main results. The FLASH skin-sparing effect was statistically indistinguishable for all experimentally tested UHDR configurations at the 23.6 Gy and 25.2 Gy dose levels. Mixed-effects regression analysis demonstrated that all four UHDR groups developed significantly lower skin toxicity scores compared to the CDR group (p < 0.05). At the highest dose level (25.9 Gy), no significant differences were observed among any radiation groups, which was attributed to a saturation effect of the visual skin score assay at severe damage thresholds. In vivo oximetry showed that tissue oxygen resupply accelerated during UHDR treatment, driven by localized concentration gradients and amplified post-RT by acute biological mechanisms. Significance. This study represents a promising step toward UHDR multi-beam delivery, a prerequisite for clinical conformal treatment planning. Multiple UHDR beams delivered within five seconds provide a statistically indistinguishable degree of normal tissue sparing as a single UHDR beam. Furthermore, the observed tissue oxygen dynamics reveal an acute biological response potentially unique to UHDR delivery, shedding light on a novel physiological component of the FLASH mechanism.

Physics in Medicine and Biology
Dartmouth College (US)
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon