Impact of examination geometry on radiation dose to patient and operator during interventional procedures

Background In interventional radiology, staff radiation exposure mainly originates from patient-scattered radiation. While standard protective tools are used, examination geometry, especially detector positioning and X-ray field size, critically influences both patient and operator doses. Quantitative data on these effects under controlled experimental conditions are limited. Aims To quantify the influence of examination geometry on patient and operator radiation doses and identify configurations minimising radiation exposure. Methods Measurements were performed using an Artis Q angiography system and polymethyl methacrylate phantoms measuring 17 cm and 25 cm in thickness, positioned at a height of 95 cm above the floor to simulate abdominal geometry. Kerma-area product (P KA ), air kerma at the interventional reference point (IRP), and operator personal dose equivalent Hp(10) measured at heights of 105, 135, and 165 cm above the floor, were recorded for different phantom-to-detector distances and X-ray field sizes. Operator dose was measured using the RaySafe i3 system. Results Increasing phantom thickness increased operator dose by an average factor of 4.0 (range, 1.8–6.8). For the large phantom and large X-ray field, air kerma at the IRP increased from 9.8 to 12.9 mGy per acquisition as the phantom-to-detector distance increased. Operator dose increased by up to 77% with a larger X-ray field and by more than 60% with increasing phantom-to-detector distance. Identical P KA values were obtained for different examination geometries, despite markedly different operator doses. Dose readings measured on top of the detector were below the detection limit of the dosimetry system in all measurements. Conclusion Examination geometry influences both patient dose indicators and operator dose. Reducing X-ray field size decreases P KA and operator dose, although air kerma at the IRP may increase slightly. Within the geometries investigated, a shorter patient-to-detector distance was associated with lower operator dose. Identical P KA values do not necessarily imply identical operator doses.

Authors

Institutions

Publication Details

Journal
Irish Journal of Medical Science (1971 -)
Published
2026-11-19
DOI
https://doi.org/10.1007/s11845-026-04728-x
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Impact of examination geometry on radiation dose to patient and operator during interventional procedures

Lucie Súkupová
Irish Journal of Medical Science (1971 -)
Radiation Dose and Imaging
article

Impact of examination geometry on radiation dose to patient and operator during interventional procedures

Lucie Súkupová
article en

Abstract

Background In interventional radiology, staff radiation exposure mainly originates from patient-scattered radiation. While standard protective tools are used, examination geometry, especially detector positioning and X-ray field size, critically influences both patient and operator doses. Quantitative data on these effects under controlled experimental conditions are limited. Aims To quantify the influence of examination geometry on patient and operator radiation doses and identify configurations minimising radiation exposure. Methods Measurements were performed using an Artis Q angiography system and polymethyl methacrylate phantoms measuring 17 cm and 25 cm in thickness, positioned at a height of 95 cm above the floor to simulate abdominal geometry. Kerma-area product (P KA ), air kerma at the interventional reference point (IRP), and operator personal dose equivalent Hp(10) measured at heights of 105, 135, and 165 cm above the floor, were recorded for different phantom-to-detector distances and X-ray field sizes. Operator dose was measured using the RaySafe i3 system. Results Increasing phantom thickness increased operator dose by an average factor of 4.0 (range, 1.8–6.8). For the large phantom and large X-ray field, air kerma at the IRP increased from 9.8 to 12.9 mGy per acquisition as the phantom-to-detector distance increased. Operator dose increased by up to 77% with a larger X-ray field and by more than 60% with increasing phantom-to-detector distance. Identical P KA values were obtained for different examination geometries, despite markedly different operator doses. Dose readings measured on top of the detector were below the detection limit of the dosimetry system in all measurements. Conclusion Examination geometry influences both patient dose indicators and operator dose. Reducing X-ray field size decreases P KA and operator dose, although air kerma at the IRP may increase slightly. Within the geometries investigated, a shorter patient-to-detector distance was associated with lower operator dose. Identical P KA values do not necessarily imply identical operator doses.

Irish Journal of Medical Science (1971 -)
Institute of Clinical and Experimental Medicine (CZ)
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon