A new gel containing a recombinant hybrid cystatin (CaneStat) and vitamin E protects against initial extrinsic erosion in vitro
Objectives To evaluate the anti-erosive efficacy of a novel thermoresponsive Poloxamer 407 hydrogel co-delivering the recombinant hybrid protein CaneStat (CaneCPI-5 fused to a statherin-derived phosphomimetic peptide) and Vitamin E against initial extrinsic enamel erosion when applied before or after acquired enamel pellicle (AEP) formation. Methods Bovine enamel specimens ( n = 238) were allocated to seven treatment groups containing Poloxamer 407 hydrogel: Poloxamer 407 only (placebo), CaneStat (0.025 mg/mL), Vitamin E (1% or 10%), CaneStat + Vitamin E (1% or 10%), and NaF (9000 ppm F; positive control). Treatments were applied before or after 2-h acquired enamel pellicle (AEP) formation. Specimens underwent a 3-day erosive cycling model using 1% citric acid (pH 2.5, 1 min/day). Anti-erosive efficacy was assessed by percentage surface microhardness change (%SMC) and surface reflection intensity (%SRI). Results The CaneStat + 10% Vitamin E hydrogel significantly reduced enamel softening, providing protection comparable to the NaF control and superior to the placebo and individual compounds. The 1% Vitamin E formulation showed similar performance to the 10% formulation and the CaneStat-only hydrogel, although remaining slightly inferior to NaF. %SRI analysis confirmed these findings. Application before AEP formation resulted in significantly lower %SMC than application after AEP formation, whereas %SRI was not influenced by the application protocol. Conclusions The Poloxamer 407 hydrogel co-delivering CaneStat and Vitamin E effectively reduced initial extrinsic enamel erosion through biomimetic pellicle engineering, demonstrating a synergistic protective effect comparable to high-concentration fluoride. Clinical significance This biomimetic hydrogel remained effective even when applied after AEP formation, highlighting its potential as a clinically relevant, patient-friendly strategy for preventing dental erosion.
Authors
- Valentine Spagnol (ORCID: https://orcid.org/0009-0007-4530-1770)
- Marília Afonso Rabelo Buzalaf (ORCID: https://orcid.org/0000-0002-5985-3951)
- Thiago Saads Carvalho (ORCID: https://orcid.org/0000-0002-2435-1169)
- João Víctor Frazão Câmara (ORCID: https://orcid.org/0000-0002-9687-4401)
- Vinícius Taioqui Pelá (ORCID: https://orcid.org/0000-0001-7933-4422)
- Adrian Lussi (ORCID: https://orcid.org/0000-0002-0426-3364)
- Amedea Barozzi Seabra (ORCID: https://orcid.org/0000-0003-0591-0380)
- Daniela Ríos (ORCID: https://orcid.org/0000-0002-9162-3654)
- Leonardo Brito (ORCID: https://orcid.org/0000-0003-3701-9066)
- Sônia Groisman (ORCID: https://orcid.org/0000-0003-1153-3841)
- João Guilherme Medeiros (ORCID: https://orcid.org/0009-0008-7661-7548)
Institutions
- University of Bern (CH)
- Innsbruck Medical University (AT)
- Universidade Federal de São Carlos (BR)
- Universidade de São Paulo (BR)
- Universidade do Estado do Rio de Janeiro (BR)
- Universidade Federal do ABC (BR)
- Saarland University (DE)
Publication Details
- Journal
- Clinical Oral Investigations
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1007/s00784-026-07268-x
- Primary Topic
- Dental Erosion and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00