Frequency Characteristics of High-Voltage Power Semiconductor Gate Drive Circuit Using Resonant Inductive Wireless Power Transfer

This paper investigates the frequency characteristics of a high-voltage gate-drive circuit using resonant inductive wireless power transfer (RIWPT). In the proposed RIWPT system, both the control and carrier signals are transmitted simultaneously through magnetically coupled coils, then rectified and applied to the gate of a SiC MOSFET to ensure reliable switching operation. For given amplitudes of the control and carrier signals, the achievable transfer distance is analyzed at different carrier frequencies. For the 44-turn α-wound coil, with a 15-V control signal and a 30-V carrier signal, a maximum power transfer distance of 151 mm is obtained at a carrier frequency of approximately 260 kHz. For the 44-turn spiral coil, with the same control signal and a 10-V carrier signal, a maximum transfer distance of 200 mm is achieved at a carrier frequency of approximately 193 kHz. Both maximum transfer distances satisfy the required coil separation distance to ensure adequate insulation for a system operating at a high voltage of 28.3 kV. Furthermore, the frequency-dependent variation in the turn-on and turn-off times with respect to the carrier frequency and gate–source drive voltage is also investigated. Based on the analysis, an optimization is implemented through simulation. The optimized turn-on and turn-off time are significantly reduced to 14 µs and 7 µs, respectively. In this paper, the presented results are all based on electromagnetic simulations using Ansys Maxwell and circuit simulations using Keysight ADS. In our future work, experimental validation of the proposed RIWPT gate-drive system will be conducted to verify the simulation results and further evaluate its practical feasibility under high-voltage operating conditions.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Computational Intelligence and Intelligent Informatics
Published
2026-11-20
DOI
https://doi.org/10.20965/jaciii.2026.p1979
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Frequency Characteristics of High-Voltage Power Semiconductor Gate Drive Circuit Using Resonant Inductive Wireless Power Transfer

Takeshi Shinkai, Dong Yue, Li Ning
Journal of Advanced Computational Intelligence and Intelligent Informatics
Wireless Power Transfer Systems
article

Frequency Characteristics of High-Voltage Power Semiconductor Gate Drive Circuit Using Resonant Inductive Wireless Power Transfer

Takeshi Shinkai, Dong Yue, Li Ning
article en

Abstract

This paper investigates the frequency characteristics of a high-voltage gate-drive circuit using resonant inductive wireless power transfer (RIWPT). In the proposed RIWPT system, both the control and carrier signals are transmitted simultaneously through magnetically coupled coils, then rectified and applied to the gate of a SiC MOSFET to ensure reliable switching operation. For given amplitudes of the control and carrier signals, the achievable transfer distance is analyzed at different carrier frequencies. For the 44-turn α-wound coil, with a 15-V control signal and a 30-V carrier signal, a maximum power transfer distance of 151 mm is obtained at a carrier frequency of approximately 260 kHz. For the 44-turn spiral coil, with the same control signal and a 10-V carrier signal, a maximum transfer distance of 200 mm is achieved at a carrier frequency of approximately 193 kHz. Both maximum transfer distances satisfy the required coil separation distance to ensure adequate insulation for a system operating at a high voltage of 28.3 kV. Furthermore, the frequency-dependent variation in the turn-on and turn-off times with respect to the carrier frequency and gate–source drive voltage is also investigated. Based on the analysis, an optimization is implemented through simulation. The optimized turn-on and turn-off time are significantly reduced to 14 µs and 7 µs, respectively. In this paper, the presented results are all based on electromagnetic simulations using Ansys Maxwell and circuit simulations using Keysight ADS. In our future work, experimental validation of the proposed RIWPT gate-drive system will be conducted to verify the simulation results and further evaluate its practical feasibility under high-voltage operating conditions.

Journal of Advanced Computational Intelligence and Intelligent InformaticsVol. 30(6)
Tokyo University of Technology (JP), Nanjing University of Posts and Telecommunications (CN)
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon