Robust position-misalignment calibration architecture with spectral decoupling for Fourier ptychographic microscopy

SignificanceBalancing computational efficiency and light-emitting diode calibration accuracy remains a major challenge in Fourier ptychographic microscopy (FPM).AimWe present a robust calibration framework based on spectral decoupling and artifact suppression, termed SAAS-FPM.ApproachUnlike conventional methods that estimate parameters directly from full or naively cropped spectra, the proposed method addresses the mechanism by which cross-shaped spectral coherence artifacts induced by compressed imaging regions destabilize the position-search process. By incorporating an improved periodic-plus-smooth image decomposition method as a physics-informed prior, SAAS-FPM decouples spatial boundary discontinuities from intrinsic structural features in low-resolution spectra. Localized mean interpolation and energy compensation are then used to restore spectral features affected by the artifact distribution, thereby reducing feature-extraction errors within compressed imaging regions.ResultsExperimental results demonstrate that SAAS-FPM improves the trade-off between computational cost and calibration robustness: the proposed framework reduces execution time by more than 14.2% and decreases the simulated annealing search error by more than 51.1% while maintaining high localization precision.ConclusionsThese findings provide a robust and efficient system-calibration strategy for large-scale, high-throughput computational microscopy.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Optics
Published
2026-11-18
DOI
https://doi.org/10.1117/1.jbo.31.11.116501
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Robust position-misalignment calibration architecture with spectral decoupling for Fourier ptychographic microscopy

Jiaxiong Luo, Junrui Zhen, Yanxiong Wu, Junzhao Liang et al.
Journal of Biomedical Optics
Advanced X-ray Imaging Techniques
article

Robust position-misalignment calibration architecture with spectral decoupling for Fourier ptychographic microscopy

Jiaxiong Luo, Junrui Zhen, Yanxiong Wu, Junzhao Liang, Mingdi Liu
article en

Abstract

SignificanceBalancing computational efficiency and light-emitting diode calibration accuracy remains a major challenge in Fourier ptychographic microscopy (FPM).AimWe present a robust calibration framework based on spectral decoupling and artifact suppression, termed SAAS-FPM.ApproachUnlike conventional methods that estimate parameters directly from full or naively cropped spectra, the proposed method addresses the mechanism by which cross-shaped spectral coherence artifacts induced by compressed imaging regions destabilize the position-search process. By incorporating an improved periodic-plus-smooth image decomposition method as a physics-informed prior, SAAS-FPM decouples spatial boundary discontinuities from intrinsic structural features in low-resolution spectra. Localized mean interpolation and energy compensation are then used to restore spectral features affected by the artifact distribution, thereby reducing feature-extraction errors within compressed imaging regions.ResultsExperimental results demonstrate that SAAS-FPM improves the trade-off between computational cost and calibration robustness: the proposed framework reduces execution time by more than 14.2% and decreases the simulated annealing search error by more than 51.1% while maintaining high localization precision.ConclusionsThese findings provide a robust and efficient system-calibration strategy for large-scale, high-throughput computational microscopy.

Journal of Biomedical OpticsVol. 31(11)
Foshan University (CN)
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon