A single-pump technique for sequential aspiration through two catheter routes during mechanical thrombectomy

Aspiration is often required through multiple routes during mechanical thrombectomy, particularly when balloon-guiding and coaxial aspiration catheters are used. Managing multiple aspiration lines can increase procedural complexity and require additional personnel or equipment. We describe a simple system that enables aspiration from two routes using a single mechanical aspiration pump. By switching a three-way stopcock, negative pressure is maintained in the distal aspiration catheter while aspiration is applied through another catheter route. This preliminary technique may simplify aspiration management in resource- or personnel-limited settings; however, further experimental validation is required to establish its reliability and safety.

Authors

Publication Details

Journal
The Egyptian Journal of Neurosurgery : the official publication of the Egyptian Society of Neurological Surgeons/Egyptian journal of neurosurgery
Published
2026-11-19
DOI
https://doi.org/10.1186/s41984-026-00717-5
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A single-pump technique for sequential aspiration through two catheter routes during mechanical thrombectomy

Yuya Kobayashi, Yoshiki Sekijima, Miho Kurashina, Ryotaro Yui
The Egyptian Journal of Neurosurgery : the official publication of the Egyptian Society of Neurological Surgeons/Egyptian journal of neurosurgery
Acute Ischemic Stroke Management
article

A single-pump technique for sequential aspiration through two catheter routes during mechanical thrombectomy

Yuya Kobayashi, Yoshiki Sekijima, Miho Kurashina, Ryotaro Yui
article en

Abstract

Aspiration is often required through multiple routes during mechanical thrombectomy, particularly when balloon-guiding and coaxial aspiration catheters are used. Managing multiple aspiration lines can increase procedural complexity and require additional personnel or equipment. We describe a simple system that enables aspiration from two routes using a single mechanical aspiration pump. By switching a three-way stopcock, negative pressure is maintained in the distal aspiration catheter while aspiration is applied through another catheter route. This preliminary technique may simplify aspiration management in resource- or personnel-limited settings; however, further experimental validation is required to establish its reliability and safety.

The Egyptian Journal of Neurosurgery : the official publication of the Egyptian Society of Neurological Surgeons/Egyptian journal of neurosurgeryVol. 41(1)
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.