Development and Evaluation of a Cap-Mounted Tripolar Concentric Ring Electrode System with a Central Gel-Delivery Opening for tEEG and EEG Recording

Electroencephalography (EEG) commonly uses conventional disc electrodes with conductive gel or paste to record electrical activity from the scalp. However, conventional disc electrodes have limited spatial selectivity because they detect electrical activity spreading from different brain regions. Tripolar concentric ring electrodes (TCREs) have been developed to improve spatial selectivity by estimating the scalp surface Laplacian. Nevertheless, establishing electrical contact at hair-bearing scalp locations remains challenging. To address this challenge, we developed a modified gold-plated copper TCRE with a 2 mm central opening for conductive gel delivery and a custom 3D-printed cap-mounted holder. After electrode placement, conductive gel is delivered through the opening to establish electrical contact between the metallic contacts and the scalp beneath the hair. The system was evaluated in ten healthy adults using eyes-open/eyes-closed resting-state EEG and pattern-reversal checkerboard visual stimulation. For the experimental recordings, two modified TCREs were positioned at the occipital scalp locations O1 and O2, where conductive gel was delivered through their central openings to establish electrical contact with the scalp. A third TCRE was positioned at Pz and coupled using conductive paste, while a separate conventional disc electrode was placed 1 cm superior to Pz. Recordings from these electrode configurations were analyzed to evaluate resting-state alpha activity, visual evoked potentials (VEPs), and signal quality. Each TCRE provided tripolar EEG (tEEG) and EEG Emulator (eEEG) signals. The modified TCREs recorded identifiable VEP components, with negative and positive peaks near 105 and 141 ms, respectively, along with stimulus-related spectral activity. The eEEG VEP waveforms at O1 and O2 showed strong correlations with Pz eEEG (median r=0.897 and 0.938, respectively). Alpha-band power also increased significantly during eye closure in both gel-coupled tEEG channels (Holm-adjusted p=0.0195). Impedance measurements, signal-quality analyses, and circuit modeling provided additional characterization of the system. These findings support the feasibility of acquiring tEEG and eEEG signals using the modified TCRE system at hair-bearing scalp locations.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-19
DOI
https://doi.org/10.3390/s26227330
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and Evaluation of a Cap-Mounted Tripolar Concentric Ring Electrode System with a Central Gel-Delivery Opening for tEEG and EEG Recording

Walter G. Besio, Maryam Norouzi, Behtom Adeli
Sensors
EEG and Brain-Computer Interfaces
article

Development and Evaluation of a Cap-Mounted Tripolar Concentric Ring Electrode System with a Central Gel-Delivery Opening for tEEG and EEG Recording

Walter G. Besio, Maryam Norouzi, Behtom Adeli
article en

Abstract

Electroencephalography (EEG) commonly uses conventional disc electrodes with conductive gel or paste to record electrical activity from the scalp. However, conventional disc electrodes have limited spatial selectivity because they detect electrical activity spreading from different brain regions. Tripolar concentric ring electrodes (TCREs) have been developed to improve spatial selectivity by estimating the scalp surface Laplacian. Nevertheless, establishing electrical contact at hair-bearing scalp locations remains challenging. To address this challenge, we developed a modified gold-plated copper TCRE with a 2 mm central opening for conductive gel delivery and a custom 3D-printed cap-mounted holder. After electrode placement, conductive gel is delivered through the opening to establish electrical contact between the metallic contacts and the scalp beneath the hair. The system was evaluated in ten healthy adults using eyes-open/eyes-closed resting-state EEG and pattern-reversal checkerboard visual stimulation. For the experimental recordings, two modified TCREs were positioned at the occipital scalp locations O1 and O2, where conductive gel was delivered through their central openings to establish electrical contact with the scalp. A third TCRE was positioned at Pz and coupled using conductive paste, while a separate conventional disc electrode was placed 1 cm superior to Pz. Recordings from these electrode configurations were analyzed to evaluate resting-state alpha activity, visual evoked potentials (VEPs), and signal quality. Each TCRE provided tripolar EEG (tEEG) and EEG Emulator (eEEG) signals. The modified TCREs recorded identifiable VEP components, with negative and positive peaks near 105 and 141 ms, respectively, along with stimulus-related spectral activity. The eEEG VEP waveforms at O1 and O2 showed strong correlations with Pz eEEG (median r=0.897 and 0.938, respectively). Alpha-band power also increased significantly during eye closure in both gel-coupled tEEG channels (Holm-adjusted p=0.0195). Impedance measurements, signal-quality analyses, and circuit modeling provided additional characterization of the system. These findings support the feasibility of acquiring tEEG and eEEG signals using the modified TCRE system at hair-bearing scalp locations.

SensorsVol. 26(22)
University of Rhode Island (US)
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon