Speech-in-Noise and Music Perception after Wireless Loudness-Balanced Bimodal Fitting in Adult Cochlear Implant Users: A Longitudinal Observational Study

Objective: To investigate longitudinal changes in speech-in-noise and music perception in adult cochlear implant users with a contralateral residual hearing after a standardized bimodal fitting protocol based on wireless interaural loudness balancing between the cochlear implant and hearing aid. Design: Prospective observational within-subject longitudinal study of adult bimodal cochlear implant users undergoing a standardized wireless loudness-balancing fitting protocol, with repeated assessments at baseline and after 3, 6, 9, and 12 months. Study Sample: Twelve post-lingually deaf adult cochlear implant users (eight men and four women; mean age, 60 years; range, 27–80 years) with severe-to-profound hearing loss in the implanted ear and usable residual hearing in the contralateral ear. Results: The standardized wireless loudness-balanced bimodal fitting protocol was associated with consistently better speech-in-noise performance in the bimodal condition than in the cochlear implant-only condition, with advantages in SRT50-derived binaural indices. Music perception was systematically better in the bimodal condition, particularly for pitch and rhythm discrimination, with more gradual and variable gains for harmony and instrument recognition. SSQ scores improved over the 12-month follow-up, suggesting reduced self-reported listening difficulty in everyday auditory situations. Conclusions: A standardized bimodal fitting protocol incorporating wireless interaural loudness balancing was associated with clinically relevant improvements in speech-in-noise performance and selected dimensions of music perception in adult cochlear implant users with contralateral residual hearing. Because no non-balanced control condition was included, the observed benefits should be interpreted as outcomes of an optimized bimodal fitting strategy rather than as definitive evidence of superiority of wireless loudness balancing over other fitting procedures.

Authors

Publication Details

Journal
Audiology and Neurotology
Published
2026-11-19
DOI
https://doi.org/10.1159/aud/abnag021
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Speech-in-Noise and Music Perception after Wireless Loudness-Balanced Bimodal Fitting in Adult Cochlear Implant Users: A Longitudinal Observational Study

Paolo Malerba, Mara Casulli, Adriana Ardito, Alessandra Murri et al.
Audiology and Neurotology
Hearing Loss and Rehabilitation
article

Speech-in-Noise and Music Perception after Wireless Loudness-Balanced Bimodal Fitting in Adult Cochlear Implant Users: A Longitudinal Observational Study

Paolo Malerba, Mara Casulli, Adriana Ardito, Alessandra Murri, Francesco Salonna, Nicola QUARANTA, Giannandrea Nitais, Fabio Iacobellis
article en

Abstract

Objective: To investigate longitudinal changes in speech-in-noise and music perception in adult cochlear implant users with a contralateral residual hearing after a standardized bimodal fitting protocol based on wireless interaural loudness balancing between the cochlear implant and hearing aid. Design: Prospective observational within-subject longitudinal study of adult bimodal cochlear implant users undergoing a standardized wireless loudness-balancing fitting protocol, with repeated assessments at baseline and after 3, 6, 9, and 12 months. Study Sample: Twelve post-lingually deaf adult cochlear implant users (eight men and four women; mean age, 60 years; range, 27–80 years) with severe-to-profound hearing loss in the implanted ear and usable residual hearing in the contralateral ear. Results: The standardized wireless loudness-balanced bimodal fitting protocol was associated with consistently better speech-in-noise performance in the bimodal condition than in the cochlear implant-only condition, with advantages in SRT50-derived binaural indices. Music perception was systematically better in the bimodal condition, particularly for pitch and rhythm discrimination, with more gradual and variable gains for harmony and instrument recognition. SSQ scores improved over the 12-month follow-up, suggesting reduced self-reported listening difficulty in everyday auditory situations. Conclusions: A standardized bimodal fitting protocol incorporating wireless interaural loudness balancing was associated with clinically relevant improvements in speech-in-noise performance and selected dimensions of music perception in adult cochlear implant users with contralateral residual hearing. Because no non-balanced control condition was included, the observed benefits should be interpreted as outcomes of an optimized bimodal fitting strategy rather than as definitive evidence of superiority of wireless loudness balancing over other fitting procedures.

Audiology and Neurotology
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon