Junction-referenced dual-mode scanning thermal microscopy with W-Cr ultra-thin oxide tip probes

Quantitative scanning thermal microscopy (SThM) uses different temperature references for thermocouple and thermoresistive measurements, limiting comparison and cross-validation. Here, we establish the first junction-referenced dual-mode SThM methodology that calibrates and characterizes both responses of a tungsten-chromium (W-Cr) ultra-thin oxide tip (UTOT) probe against a common junction-temperature-rise reference. Vacuum null-point SThM calibrates the room temperature Seebeck coefficient, which, together with the initial voltage-power slope, determines the low-power effective thermal resistance. The high-temperature axis uses the first-order approximation T j ≈ R p P . We determine effective thermal resistance, Seebeck coefficient, thermal time constant, electrical resistance, and junction-referenced effective temperature coefficient of resistance (TCR) in air and vacuum. Practical power-sweep limits correspond to estimated junction-temperature rises of approximately 300°C in air and 400°C in vacuum. R ( T j ) maps the thermoresistive response onto the common junction-temperature axis, enabling comparison of both readouts and providing a basis for cross-validation.

Authors

Institutions

Publication Details

Journal
iScience
Published
2026-11-19
DOI
https://doi.org/10.1016/j.isci.2026.118270
Primary Topic
Thermal properties of materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Junction-referenced dual-mode scanning thermal microscopy with W-Cr ultra-thin oxide tip probes

Hwijong Shin, Ohmyoung Kwon, Younghyun Kim
iScience
Thermal properties of materials
article

Junction-referenced dual-mode scanning thermal microscopy with W-Cr ultra-thin oxide tip probes

Hwijong Shin, Ohmyoung Kwon, Younghyun Kim
article en

Abstract

Quantitative scanning thermal microscopy (SThM) uses different temperature references for thermocouple and thermoresistive measurements, limiting comparison and cross-validation. Here, we establish the first junction-referenced dual-mode SThM methodology that calibrates and characterizes both responses of a tungsten-chromium (W-Cr) ultra-thin oxide tip (UTOT) probe against a common junction-temperature-rise reference. Vacuum null-point SThM calibrates the room temperature Seebeck coefficient, which, together with the initial voltage-power slope, determines the low-power effective thermal resistance. The high-temperature axis uses the first-order approximation T j ≈ R p P . We determine effective thermal resistance, Seebeck coefficient, thermal time constant, electrical resistance, and junction-referenced effective temperature coefficient of resistance (TCR) in air and vacuum. Practical power-sweep limits correspond to estimated junction-temperature rises of approximately 300°C in air and 400°C in vacuum. R ( T j ) maps the thermoresistive response onto the common junction-temperature axis, enabling comparison of both readouts and providing a basis for cross-validation.

iScienceVol. 29(12)
Korea University (KR)
Thermal properties of materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon