Association of the Early Best Response ROX Index and Admission Erector Spinae Muscle Area with High-Flow Nasal Cannula Failure: A Single-Center Retrospective Cohort Study

Background/Objectives: Failure to recognize high-flow nasal cannula (HFNC) failure early may delay intubation and worsen clinical outcomes. We investigated whether the early physiological response to HFNC and erector spinae muscle (ESM) area at admission were associated with HFNC failure in pneumonia-related acute respiratory failure. Methods: This single-center retrospective observational cohort study included adults who received HFNC within 24 h of intensive care unit admission between 2019 and 2023. HFNC failure was defined as intubation within 7 days. The Respiratory Rate–Oxygenation (ROX) index was measured before HFNC initiation. For days 1 and 2, the best response ROX index was retrospectively defined as the ROX value corresponding to the highest PaO2/ fraction of inspired oxygen ratio within each 24 h assessment window, rather than as a measurement obtained at a prespecified time point. The ESM area at T12 was measured on admission. Longitudinal changes in the ROX index and factors associated with HFNC failure were evaluated. Results: Among 94 patients, 21 experienced HFNC failure. The admission ROX index did not differ significantly between the groups (3.4 versus 3.6). The median best response ROX indices in the success and failure groups were 10.7 versus 6.6 on day 1 and 10.5 versus 6.4 on day 2. ROX improvement was significantly smaller in the failure group on both days. The day 1 best response ROX index had an area under the receiver operating characteristic curve of 0.731 (95% confidence interval [CI], 0.611–0.851). In the primary analysis using Firth penalized logistic regression (85 patients, including 17 HFNC failures), a lower day 1 best response ROX index (adjusted odds ratio [OR] per unit increase, 0.818; 95% CI, 0.692–0.931) and a smaller admission ESM area (adjusted OR per 100 mm2 increase, 0.939; 95% CI, 0.872–0.999) were associated with HFNC failure. Conclusions: The day 1 best response ROX index and admission ESM area were associated with HFNC failure. However, their clinical utility remains uncertain, and prospective multicenter studies with standardized assessment protocols and external validation are warranted.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-19
DOI
https://doi.org/10.3390/jcm15229077
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association of the Early Best Response ROX Index and Admission Erector Spinae Muscle Area with High-Flow Nasal Cannula Failure: A Single-Center Retrospective Cohort Study

Kosaku Kinoshita, Junko Yamaguchi, Hayato Nakabayashi, Ken Takahashi
Journal of Clinical Medicine
Respiratory Support and Mechanisms
article

Association of the Early Best Response ROX Index and Admission Erector Spinae Muscle Area with High-Flow Nasal Cannula Failure: A Single-Center Retrospective Cohort Study

Kosaku Kinoshita, Junko Yamaguchi, Hayato Nakabayashi, Ken Takahashi
article en

Abstract

Background/Objectives: Failure to recognize high-flow nasal cannula (HFNC) failure early may delay intubation and worsen clinical outcomes. We investigated whether the early physiological response to HFNC and erector spinae muscle (ESM) area at admission were associated with HFNC failure in pneumonia-related acute respiratory failure. Methods: This single-center retrospective observational cohort study included adults who received HFNC within 24 h of intensive care unit admission between 2019 and 2023. HFNC failure was defined as intubation within 7 days. The Respiratory Rate–Oxygenation (ROX) index was measured before HFNC initiation. For days 1 and 2, the best response ROX index was retrospectively defined as the ROX value corresponding to the highest PaO2/ fraction of inspired oxygen ratio within each 24 h assessment window, rather than as a measurement obtained at a prespecified time point. The ESM area at T12 was measured on admission. Longitudinal changes in the ROX index and factors associated with HFNC failure were evaluated. Results: Among 94 patients, 21 experienced HFNC failure. The admission ROX index did not differ significantly between the groups (3.4 versus 3.6). The median best response ROX indices in the success and failure groups were 10.7 versus 6.6 on day 1 and 10.5 versus 6.4 on day 2. ROX improvement was significantly smaller in the failure group on both days. The day 1 best response ROX index had an area under the receiver operating characteristic curve of 0.731 (95% confidence interval [CI], 0.611–0.851). In the primary analysis using Firth penalized logistic regression (85 patients, including 17 HFNC failures), a lower day 1 best response ROX index (adjusted odds ratio [OR] per unit increase, 0.818; 95% CI, 0.692–0.931) and a smaller admission ESM area (adjusted OR per 100 mm2 increase, 0.939; 95% CI, 0.872–0.999) were associated with HFNC failure. Conclusions: The day 1 best response ROX index and admission ESM area were associated with HFNC failure. However, their clinical utility remains uncertain, and prospective multicenter studies with standardized assessment protocols and external validation are warranted.

Journal of Clinical MedicineVol. 15(22)
Nihon University (JP)
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon