A Systematic Investigation of the Effect of Port Diameter on the Thermal Performance of a Corrugated Plate Heat Exchanger

The exceptional thermal performance of corrugated plate heat exchangers (CPHEs) is generally accompanied by substantial pumping power requirements. A systematic parametric assessment is essential to determine favorable CPHE configurations. Therefore, this study aims to systematically investigate the effect of the port diameter (Dp) on the thermal and hydraulic characteristics of CPHEs. Four CPHEs with Dp = 30 mm (CPHE30), Dp = 45 mm (CPHE45), Dp = 60 mm (CPHE60), and Dp = 75 mm (CPHE75) are investigated. A validated CFD methodology is employed to systematically evaluate the thermal–hydraulic response of the investigated configurations. The ratio of the heat transfer rate to the pumping power is employed as the overall thermal performance indicator (η). The results show that CPHE30 yields the highest data of the Nusselt number (Nu). Yet, the differences in Nu among the investigated port diameters are negligible. Both core and port pressure losses decrease with an increasing Dp. The port pressure drop for CPHE30 is 9–11% and 12–18% higher than that for CPHE45 and CPHE60, respectively. Overall, based on the present study, a port diameter of at least 80% of the maximum feasible diameter is recommended. Accordingly, the η values of CPHE60 are 14.7 to 20.7 and 3.7 to 6.6% greater than those of CPHE30 and CPHE45, respectively.

Authors

Institutions

Publication Details

Journal
Mathematics
Published
2026-11-19
DOI
https://doi.org/10.3390/math14224256
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Systematic Investigation of the Effect of Port Diameter on the Thermal Performance of a Corrugated Plate Heat Exchanger

Salman Al-Zahrani
Mathematics
Heat Transfer and Optimization
article

A Systematic Investigation of the Effect of Port Diameter on the Thermal Performance of a Corrugated Plate Heat Exchanger

Salman Al-Zahrani
article en

Abstract

The exceptional thermal performance of corrugated plate heat exchangers (CPHEs) is generally accompanied by substantial pumping power requirements. A systematic parametric assessment is essential to determine favorable CPHE configurations. Therefore, this study aims to systematically investigate the effect of the port diameter (Dp) on the thermal and hydraulic characteristics of CPHEs. Four CPHEs with Dp = 30 mm (CPHE30), Dp = 45 mm (CPHE45), Dp = 60 mm (CPHE60), and Dp = 75 mm (CPHE75) are investigated. A validated CFD methodology is employed to systematically evaluate the thermal–hydraulic response of the investigated configurations. The ratio of the heat transfer rate to the pumping power is employed as the overall thermal performance indicator (η). The results show that CPHE30 yields the highest data of the Nusselt number (Nu). Yet, the differences in Nu among the investigated port diameters are negligible. Both core and port pressure losses decrease with an increasing Dp. The port pressure drop for CPHE30 is 9–11% and 12–18% higher than that for CPHE45 and CPHE60, respectively. Overall, based on the present study, a port diameter of at least 80% of the maximum feasible diameter is recommended. Accordingly, the η values of CPHE60 are 14.7 to 20.7 and 3.7 to 6.6% greater than those of CPHE30 and CPHE45, respectively.

MathematicsVol. 14(22)
Al Baha University (SA)
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon