Crosslinker-associated swelling–protein response relationships in compositionally matched MPC hydrogels for biomedical interfaces

Nonspecific protein accumulation at material–biological interfaces can compromise biomedical device performance. This study investigated crosslinker-associated swelling and SDS-recoverable protein responses in 2-methacryloyloxyethyl phosphorylcholine (MPC)-based hydrogels. M85-BMEP and M85-EGDMA were prepared with the same MPC/ethyl methacrylate ratio (85/15, w/w), nominal crosslinker content (2 mol%), and polymerization conditions, differing only in crosslinker type: phosphate-containing bis[2-(methacryloyloxy)ethyl] phosphate (BMEP) or ethylene glycol dimethacrylate (EGDMA). M100-BMEP was included as an additional formulation. FTIR, EDX, SEM, and gravimetric swelling characterized the hydrogels; SDS-recoverable protein was quantified after exposure to BSA and 20-fold-diluted commercial human serum. In PBS, M85-BMEP and M85-EGDMA exhibited similar swelling ratios (5.23 ± 0.66 and 5.17 ± 0.74 g/g , respectively; p = 0.994 ), despite markedly different SDS-recoverable protein responses. External-area-normalized BSA recovery was 5.247 ± 0.325, 11.283 ± 0.534, and 20.300 ± 0.741 μ g cm − 2 , while serum-protein recovery (BSA equivalents) was 3.630 ± 0.426, 16.523 ± 0.794, and 21.617 ± 0.438 μ g cm − 2 for M100-BMEP, M85-BMEP, and M85-EGDMA, respectively. All pairwise comparisons of area-normalized protein recovery were significant in both environments ( p < 0.001 ). Within the matched M85 pair, M85-BMEP exhibited approximately 44% lower BSA recovery and 24% lower serum-protein recovery than M85-EGDMA, retaining the same ranking after dry-mass normalization. These findings highlight crosslinker selection as an important formulation variable for MPC-based hydrogel interfaces.

Authors

Institutions

Publication Details

Journal
Engineering Science and Technology an International Journal
Published
2026-11-19
DOI
https://doi.org/10.1016/j.jestch.2026.102596
Primary Topic
Hydrogels: synthesis, properties, applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Crosslinker-associated swelling–protein response relationships in compositionally matched MPC hydrogels for biomedical interfaces

Nursel Karaoğlan, Didem Coşkun
Engineering Science and Technology an International Journal
Hydrogels: synthesis, properties, applications
article

Crosslinker-associated swelling–protein response relationships in compositionally matched MPC hydrogels for biomedical interfaces

Nursel Karaoğlan, Didem Coşkun
article en

Abstract

Nonspecific protein accumulation at material–biological interfaces can compromise biomedical device performance. This study investigated crosslinker-associated swelling and SDS-recoverable protein responses in 2-methacryloyloxyethyl phosphorylcholine (MPC)-based hydrogels. M85-BMEP and M85-EGDMA were prepared with the same MPC/ethyl methacrylate ratio (85/15, w/w), nominal crosslinker content (2 mol%), and polymerization conditions, differing only in crosslinker type: phosphate-containing bis[2-(methacryloyloxy)ethyl] phosphate (BMEP) or ethylene glycol dimethacrylate (EGDMA). M100-BMEP was included as an additional formulation. FTIR, EDX, SEM, and gravimetric swelling characterized the hydrogels; SDS-recoverable protein was quantified after exposure to BSA and 20-fold-diluted commercial human serum. In PBS, M85-BMEP and M85-EGDMA exhibited similar swelling ratios (5.23 ± 0.66 and 5.17 ± 0.74 g/g , respectively; p = 0.994 ), despite markedly different SDS-recoverable protein responses. External-area-normalized BSA recovery was 5.247 ± 0.325, 11.283 ± 0.534, and 20.300 ± 0.741 μ g cm − 2 , while serum-protein recovery (BSA equivalents) was 3.630 ± 0.426, 16.523 ± 0.794, and 21.617 ± 0.438 μ g cm − 2 for M100-BMEP, M85-BMEP, and M85-EGDMA, respectively. All pairwise comparisons of area-normalized protein recovery were significant in both environments ( p < 0.001 ). Within the matched M85 pair, M85-BMEP exhibited approximately 44% lower BSA recovery and 24% lower serum-protein recovery than M85-EGDMA, retaining the same ranking after dry-mass normalization. These findings highlight crosslinker selection as an important formulation variable for MPC-based hydrogel interfaces.

Engineering Science and Technology an International JournalVol. 85
Karabük University (TR)
Hydrogels: synthesis, properties, applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon