Sequence analysis shows that probe sets labelled for lncRNAs can match other genes

A microarray probe set may match its labelled gene and still match other genes, making its measurements difficult to interpret as gene-specific. We examined 14 earlier GPL570 probe sets and 100 selected from 2,209 eligible sets. Of the 100 additional sets, 15 had exact matches to other genes in the original orientation (sequences as supplied; 15%; approximate 95% Wilson confidence interval, 9.3–23.3%). In five sets, all 11 oligonucleotides matched one alternative gene; in ten, fewer than 11 matched any single alternative. Two probe sets labelled CEP170P1 matched CEP170 with all 11 oligonucleotides but had no exact original-orientation match to CEP170P1 in either reference. An earlier CYTOR probe set matched both CYTOR and MIR4435-2HG with all 11 oligonucleotides. These cases show that a probe set may fail to match its labelled gene or may match both that gene and another. We also identified probe sets with oligonucleotides matching their labelled gene only after reverse complementation. Our open-source software lets researchers inspect the matching records for each probe set. These checks identify measurements needing annotation review or experimental follow-up before gene-specific interpretation. Sequence matches alone do not establish which transcripts contribute to the signal.

Authors

Publication Details

Journal
Journal of Bioinformatics and Computational Biology
Published
2026-11-19
DOI
https://doi.org/10.1142/s0219720026500162
Primary Topic
Gene expression and cancer classification
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sequence analysis shows that probe sets labelled for lncRNAs can match other genes

Xinqiu Li, Yuanning Zhang
Journal of Bioinformatics and Computational Biology
Gene expression and cancer classification
article

Sequence analysis shows that probe sets labelled for lncRNAs can match other genes

Xinqiu Li, Yuanning Zhang
article en

Abstract

A microarray probe set may match its labelled gene and still match other genes, making its measurements difficult to interpret as gene-specific. We examined 14 earlier GPL570 probe sets and 100 selected from 2,209 eligible sets. Of the 100 additional sets, 15 had exact matches to other genes in the original orientation (sequences as supplied; 15%; approximate 95% Wilson confidence interval, 9.3–23.3%). In five sets, all 11 oligonucleotides matched one alternative gene; in ten, fewer than 11 matched any single alternative. Two probe sets labelled CEP170P1 matched CEP170 with all 11 oligonucleotides but had no exact original-orientation match to CEP170P1 in either reference. An earlier CYTOR probe set matched both CYTOR and MIR4435-2HG with all 11 oligonucleotides. These cases show that a probe set may fail to match its labelled gene or may match both that gene and another. We also identified probe sets with oligonucleotides matching their labelled gene only after reverse complementation. Our open-source software lets researchers inspect the matching records for each probe set. These checks identify measurements needing annotation review or experimental follow-up before gene-specific interpretation. Sequence matches alone do not establish which transcripts contribute to the signal.

Journal of Bioinformatics and Computational Biology
Gene expression and cancer classification
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon