Robust Full-State Feedback Power Decoupling Control for Grid-Forming Converters Under Line-Impedance Mismatch

Virtual synchronous generator (VSG) control can emulate inertia and damping in grid-forming converters, but active and reactive power remain coupled in low-voltage feeders with appreciable resistance. Model-based full-state feedback (FSF) can reduce this coupling, although its performance depends on the feeder parameters used by the controller. This study reproduces nominal FSF and evaluates its sensitivity to controller-side line-impedance errors. The proposed SMC-type dynamic compensation replaces static FSF compensation and is labeled SMC (sliding-mode control) in the comparisons. A reaching law driven by instantaneous power errors generates compensation rates via an estimated Jacobian. These rates are integrated to obtain angle and voltage corrections, without forming an integral sliding surface. A local reduced-order analysis gives a conditional ultimate-error bound under bounded residual disturbances, inactive limiters, and fast inner-loop tracking. Comparative simulations include power-command steps, grid-voltage and frequency disturbances, and a nine-point resistance–inductance estimation grid. SMC improves active-power settling at the sampled grid points. In one mismatch test with identical output slew-rate and amplitude limits, both controllers settle, but SMC settles faster and reduces the peak cross-channel deviation.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-19
DOI
https://doi.org/10.3390/app162211485
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Robust Full-State Feedback Power Decoupling Control for Grid-Forming Converters Under Line-Impedance Mismatch

Jian Shen, H W Chen, Shu Yang, Qing Wang et al.
Applied Sciences
Microgrid Control and Optimization
article

Robust Full-State Feedback Power Decoupling Control for Grid-Forming Converters Under Line-Impedance Mismatch

Jian Shen, H W Chen, Shu Yang, Qing Wang, Zhengjian Chen, Hong Liu
article en

Abstract

Virtual synchronous generator (VSG) control can emulate inertia and damping in grid-forming converters, but active and reactive power remain coupled in low-voltage feeders with appreciable resistance. Model-based full-state feedback (FSF) can reduce this coupling, although its performance depends on the feeder parameters used by the controller. This study reproduces nominal FSF and evaluates its sensitivity to controller-side line-impedance errors. The proposed SMC-type dynamic compensation replaces static FSF compensation and is labeled SMC (sliding-mode control) in the comparisons. A reaching law driven by instantaneous power errors generates compensation rates via an estimated Jacobian. These rates are integrated to obtain angle and voltage corrections, without forming an integral sliding surface. A local reduced-order analysis gives a conditional ultimate-error bound under bounded residual disturbances, inactive limiters, and fast inner-loop tracking. Comparative simulations include power-command steps, grid-voltage and frequency disturbances, and a nine-point resistance–inductance estimation grid. SMC improves active-power settling at the sampled grid points. In one mismatch test with identical output slew-rate and amplitude limits, both controllers settle, but SMC settles faster and reduces the peak cross-channel deviation.

Applied SciencesVol. 16(22)
Shenzhen University (CN), Tsinghua Shenzhen International Graduate School (CN), South China University of Technology (CN)
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon