A neonatal prediction model for lower-extremity peripherally inserted central catheters depth

To develop a robust and generalizable prediction model for PICC depth in neonates undergoing lower-extremity catheterization, with the aim of improving the first-attempt success rate of catheter tip positioning and reducing PICC-related complications. A total of 240 neonates who successfully underwent lower-extremity PICC placement in the neonatal intensive care unit of a maternal and child health hospital were enrolled as study subjects. Variable selection was performed using stepwise regression based on the Akaike information criterion, followed by development of a multiple linear regression model. Internal validation was performed using the random split sample method (8:2). Model performance was assessed using root mean square error, mean absolute error, coefficient of determination (R2), and Pearson’s correlation coefficient. The final model included two simple and objective variables: body weight on the day of catheterization and puncture site. The prediction equation was established as follows: insertion depth (cm) = 17.3 + body weight at catheterization (kg) × 2.3 − adjustment value for the puncture site (2.7 for small saphenous vein, 4.5 for popliteal vein, 5.1 for popliteal great saphenous vein, and 10.3 for femoral vein, respectively; reference: ankle great saphenous vein). Internal validation showed that the model achieved an R2 of 0.8789, RMSE of 1.0754, MAE of 0.8157, and Pearson’s correlation coefficient of 0.9375 between the predicted and observed values. Residual diagnostics indicated good predictive accuracy and stability. The prediction model for neonatal lower extremity PICC insertion depth based on body weight at the catheterization and puncture sites demonstrated good fit and reliable predictive performance. It can assist in individualizing and precisely determining the catheter insertion depth in clinical practice, thereby reducing repeated adjustments and complications.

Authors

Publication Details

Journal
Figshare
Published
2026-11-19
DOI
https://doi.org/10.6084/m9.figshare.35055365
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A neonatal prediction model for lower-extremity peripherally inserted central catheters depth

An Qin, Hongbo Shen, Juan Zhao, Dongjian Yang et al.
Figshare
Central Venous Catheters and Hemodialysis
article

A neonatal prediction model for lower-extremity peripherally inserted central catheters depth

An Qin, Hongbo Shen, Juan Zhao, Dongjian Yang, Yi Zhou, Songhong Ye
article en

Abstract

To develop a robust and generalizable prediction model for PICC depth in neonates undergoing lower-extremity catheterization, with the aim of improving the first-attempt success rate of catheter tip positioning and reducing PICC-related complications. A total of 240 neonates who successfully underwent lower-extremity PICC placement in the neonatal intensive care unit of a maternal and child health hospital were enrolled as study subjects. Variable selection was performed using stepwise regression based on the Akaike information criterion, followed by development of a multiple linear regression model. Internal validation was performed using the random split sample method (8:2). Model performance was assessed using root mean square error, mean absolute error, coefficient of determination (R2), and Pearson’s correlation coefficient. The final model included two simple and objective variables: body weight on the day of catheterization and puncture site. The prediction equation was established as follows: insertion depth (cm) = 17.3 + body weight at catheterization (kg) × 2.3 − adjustment value for the puncture site (2.7 for small saphenous vein, 4.5 for popliteal vein, 5.1 for popliteal great saphenous vein, and 10.3 for femoral vein, respectively; reference: ankle great saphenous vein). Internal validation showed that the model achieved an R2 of 0.8789, RMSE of 1.0754, MAE of 0.8157, and Pearson’s correlation coefficient of 0.9375 between the predicted and observed values. Residual diagnostics indicated good predictive accuracy and stability. The prediction model for neonatal lower extremity PICC insertion depth based on body weight at the catheterization and puncture sites demonstrated good fit and reliable predictive performance. It can assist in individualizing and precisely determining the catheter insertion depth in clinical practice, thereby reducing repeated adjustments and complications.

Figshare
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon