Optimal RF Phase Modulation for Improved Magnetic Resonance Fingerprinting T 2 Encoding and Efficiency

Purpose To improve magnetic resonance fingerprinting (MRF) T 2 encoding by combining phase‐based T 2 encoding with optimal experiment design. Methods Six hundred–timepoint MRF sequences with jointly optimized flip angle (FA) and quadratic RF phase increment schedules were generated by minimizing their Cramér–Rao Lower Bound for tissue dependent sets of T 1 and T 2 . Sequences were optimized for 3T and 0.55T brain MRF and 0.55T prostate MRF and compared against FA‐only optimized and unoptimized (600‐ and 1000‐timepoint) sequences. Accuracy and precision were first evaluated using Monte‐Carlo Bloch simulations in a digital phantom. Additional simulations identified a spiral interleaf ordering which minimized aliasing artifacts under phase modulation. A T 1 /T 2 phantom was then used to validate simulation results. In vivo performance was assessed in nine healthy subjects, where precision was measured using bootstrap Monte‐Carlo experiments with 50 pseudo‐replicas. Results Jointly optimized sequences were found to produce T 2 maps with significantly greater accuracy and precision than unoptimized and FA‐only optimized sequences in simulation and phantom experiments ( p < 0.001). A Step 5 (37.5° between timepoints) spiral interleaf ordering minimized aliasing under phase modulation, while maintaining comparable performance without. In vivo testing in the brain and prostate revealed higher T 2 values, reduced T 2 coefficients of variation, and lower B 1 + sensitivity than unoptimized and FA‐only optimized sequence variants. Conclusion Simulation, phantom, and in vivo studies demonstrate that optimized RF phase modulation improves MRF T 2 encoding compared to unoptimized and FA‐only optimized sequences, enabling shorter exams and greater T 2 precision in the brain and pelvis at 3T and 0.55T.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-11-18
DOI
https://doi.org/10.1002/mrm.70671
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimal RF Phase Modulation for Improved Magnetic Resonance Fingerprinting T 2 Encoding and Efficiency

Christopher E. Keen, Nicole Seiberlich, Yun Jiang, Tom Griesler et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Optimal RF Phase Modulation for Improved Magnetic Resonance Fingerprinting T 2 Encoding and Efficiency

Christopher E. Keen, Nicole Seiberlich, Yun Jiang, Tom Griesler, Gregor Körzdöfer
article en

Abstract

Purpose To improve magnetic resonance fingerprinting (MRF) T 2 encoding by combining phase‐based T 2 encoding with optimal experiment design. Methods Six hundred–timepoint MRF sequences with jointly optimized flip angle (FA) and quadratic RF phase increment schedules were generated by minimizing their Cramér–Rao Lower Bound for tissue dependent sets of T 1 and T 2 . Sequences were optimized for 3T and 0.55T brain MRF and 0.55T prostate MRF and compared against FA‐only optimized and unoptimized (600‐ and 1000‐timepoint) sequences. Accuracy and precision were first evaluated using Monte‐Carlo Bloch simulations in a digital phantom. Additional simulations identified a spiral interleaf ordering which minimized aliasing artifacts under phase modulation. A T 1 /T 2 phantom was then used to validate simulation results. In vivo performance was assessed in nine healthy subjects, where precision was measured using bootstrap Monte‐Carlo experiments with 50 pseudo‐replicas. Results Jointly optimized sequences were found to produce T 2 maps with significantly greater accuracy and precision than unoptimized and FA‐only optimized sequences in simulation and phantom experiments ( p < 0.001). A Step 5 (37.5° between timepoints) spiral interleaf ordering minimized aliasing under phase modulation, while maintaining comparable performance without. In vivo testing in the brain and prostate revealed higher T 2 values, reduced T 2 coefficients of variation, and lower B 1 + sensitivity than unoptimized and FA‐only optimized sequence variants. Conclusion Simulation, phantom, and in vivo studies demonstrate that optimized RF phase modulation improves MRF T 2 encoding compared to unoptimized and FA‐only optimized sequences, enabling shorter exams and greater T 2 precision in the brain and pelvis at 3T and 0.55T.

Magnetic Resonance in Medicine
University of Michigan (US), Michigan Medicine (US), Siemens Healthineers (Germany) (DE)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon