Prefrontal hemodynamic fluctuations and functional connectivity during propofol and sevoflurane anesthesia: A functional near-infrared spectroscopy study
Background: Functional near-infrared spectroscopy (fNIRS) measures cortical hemodynamics, yet its ability to characterize anesthesia-related functional changes remains unclear. Methods: This exploratory secondary analysis used prospectively collected data from 120 female patients undergoing gynecologic laparoscopic surgery under propofol or sevoflurane anesthesia (60 per group). Twenty-channel prefrontal fNIRS recordings covered wakefulness, induction, and maintenance. Deoxygenated hemoglobin-derived amplitude of low-frequency fluctuations (ALFF), functional connectivity (FC), network topology, and within- and cross-state FC similarity were assessed. Support vector machine, logistic regression, and random forest classifiers assessed discrimination between states. Results: During induction, ALFF increased by 89.8% to 202.2% with propofol and 75.2% to 242.0% with sevoflurane across five prefrontal regions (all P < 0.001). During maintenance, mean ALFF was below awake levels, with significant reductions of 20.0% to 40.1% in three regions under sevoflurane (all P ≤ 0.019). Induction-related FC changes were limited and regionally heterogeneous. Regional FC, modularity, and global efficiency showed no significant maintenance-versus-awake differences in either group. Within-state between-subject FC similarity was significantly higher during maintenance than during wakefulness only with sevoflurane (mean difference [MD], 0.110; 95% CI, 0.054 to 0.169; P < 0.001). Cross-state between-subject FC similarity was higher for awake–maintenance than awake–induction comparisons with propofol (MD, 0.072; 95% CI, 0.055 to 0.090) and sevoflurane (MD, 0.144; 95% CI, 0.126 to 0.161; both P < 0.001). Support vector machine classification of induction versus wakefulness yielded areas under the curve (AUCs) of 0.83 (95% CI, 0.75 to 0.90) for propofol and 0.85 (95% CI, 0.78 to 0.91) for sevoflurane; maintenance-versus-awake AUCs were 0.67 (95% CI, 0.58 to 0.75) and 0.76 (95% CI, 0.68 to 0.85). Conclusions: Prefrontal fNIRS detected widespread induction-related hemodynamic changes, but the present connectivity measures provided limited discrimination between maintenance of anesthesia and wakefulness.
Authors
- Lei Hu (ORCID: https://orcid.org/0000-0001-9481-4176)
- Cheng Wang (ORCID: https://orcid.org/0000-0002-8315-6232)
- Wei Ou
- Hong Li (ORCID: https://orcid.org/0009-0009-0493-623X)
- Jing Huang(黄静)
- Zhenhu Liang
- Guiying Yang (ORCID: https://orcid.org/0000-0001-7418-3768)
- Minlin Chen
- Shanshan Zhang
- Fuhai Bai (ORCID: https://orcid.org/0009-0008-9590-1149)
Institutions
- Army Medical University (CN)
- Yanshan University (CN)
- Chongqing University of Education (CN)
Publication Details
- Journal
- Anesthesiology
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1097/aln.0000000000006486
- Primary Topic
- Anesthesia and Sedative Agents
- Type
- article
- Field-Weighted Citation Impact