The state of nuclear data for fusion activation simulations

This report compares decay-heat calculations made with four nuclear data libraries, TENDL-2025, ENDF/B-VIII.1, JEFF-4.0 and JENDL-5, against the JAEA FNS decay-heat benchmark. The main comparison uses the 2000 campaign, in which 73 foils were irradiated for five minutes in a mostly 14 MeV neutron field and their decay heat was measured for about an hour. The 1996 seven-hour campaign, with 29 foils and cooling times of up to 400 days, is compared separately and is not included in the rankings. Over the 69 elemental foils solved by all four libraries, the median deviation from the measurement (the mean absolute C/E deviation of each foil) is JENDL-5 17 percent, TENDL-2025 19 percent, JEFF-4.0 22 percent and ENDF/B-VIII.1 44 percent. No library is best everywhere: JENDL-5 on 24, JEFF-4.0 on 18, TENDL-2025 on 17 and ENDF/B-VIII.1 on 10 of the foils. For each element the report breaks the heat down by product and lists the nuclear data on which the libraries differ, and the final sections propose measurements, including enriched-isotope irradiations, that would resolve the largest differences.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-18
DOI
https://doi.org/10.48550/arxiv.2611.24653
Primary Topic
Nuclear reactor physics and engineering
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

The state of nuclear data for fusion activation simulations

J. Shimwell
arXiv (Cornell University)
Nuclear reactor physics and engineering
preprint

The state of nuclear data for fusion activation simulations

J. Shimwell
preprint en

Abstract

This report compares decay-heat calculations made with four nuclear data libraries, TENDL-2025, ENDF/B-VIII.1, JEFF-4.0 and JENDL-5, against the JAEA FNS decay-heat benchmark. The main comparison uses the 2000 campaign, in which 73 foils were irradiated for five minutes in a mostly 14 MeV neutron field and their decay heat was measured for about an hour. The 1996 seven-hour campaign, with 29 foils and cooling times of up to 400 days, is compared separately and is not included in the rankings. Over the 69 elemental foils solved by all four libraries, the median deviation from the measurement (the mean absolute C/E deviation of each foil) is JENDL-5 17 percent, TENDL-2025 19 percent, JEFF-4.0 22 percent and ENDF/B-VIII.1 44 percent. No library is best everywhere: JENDL-5 on 24, JEFF-4.0 on 18, TENDL-2025 on 17 and ENDF/B-VIII.1 on 10 of the foils. For each element the report breaks the heat down by product and lists the nuclear data on which the libraries differ, and the final sections propose measurements, including enriched-isotope irradiations, that would resolve the largest differences.

arXiv (Cornell University)
Nuclear reactor physics and engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.