Adaptive observation–history fusion for EEG-based tracking of PERCLOS-anchored drowsiness
Objective. This study evaluates explicit adaptive observation–history fusion for continuous EEG-based tracking of PERCLOS-anchored drowsiness and tests whether reward-driven proximal policy optimisation (PPO) provides predictive benefit over supervised fusion and temporal alternatives. Approach. SEED-VIG data from 21 participants and 23 recording sessions were evaluated using strict 21-fold subject-wise leave-one-subject-out (LOSO) validation. In each fold, an EEG encoder generated a PERCLOS-supervised observation proxy, which was recursively combined with the previous estimate through an adaptive observation–history fusion coefficient. Eleven primary methods spanned raw-proxy prediction, conventional filters, supervised and PPO-based fusion, and neural temporal models. Percentage of eyelid closure over time (PERCLOS) provided the ocular-behavioural reference for supervision, PPO reward construction, model selection, and evaluation. Main results. Among methods available in all 21 folds, S4D had the lowest descriptive mean root-mean-square error (RMSE; 0.240746), followed by Gate-7D (0.241490). PPO-7D was available in 20/21 folds. In the prespecified matched comparison (n = 20), the mean RMSE difference (Gate-7D minus PPO-7D) was -0.0022941 (95% bootstrap CI -0.00813595 to 0.00361267; Wilcoxon p = 0.348810), which did not establish a predictive advantage for PPO-7D. None of the 18 broader prespecified PPO-versus-alternative RMSE comparisons met its rejection criterion after Holm correction. Validation-side controlled perturbation altered the EEG-derived proxy, but the prespecified stronger reliability-response criterion was not satisfied. Significance. Explicit observation–history fusion makes the relative contributions of the current EEG proxy and recursive history inspectable. PPO yielded descriptively slower, more persistent fusion-coefficient dynamics than Gate-7D, but its predictive advantage and necessity were not established. The coefficient describes recursive weighting, not calibrated observation reliability.
Authors
- Yuan Wang Yang (ORCID: https://orcid.org/0000-0002-4225-5226)
- Wenhao Zhao (ORCID: https://orcid.org/0009-0006-1807-7630)
- Zhibo Pang
- Xueping Li (ORCID: https://orcid.org/0009-0002-4986-2886)
Institutions
- Xi'an University of Technology (CN)
- KTH Royal Institute of Technology (SE)
Publication Details
- Journal
- Physiological Measurement
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1088/1361-6579/aec49a
- Primary Topic
- EEG and Brain-Computer Interfaces
- Type
- article
- Field-Weighted Citation Impact
- 0.00