Comparative Evaluation of the Marginal Fit of Graphene-Based Crowns and Two Other Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM)-Fabricated Crown Materials: An In Vitro Study

Background and objective: Marginal adaptation is an important parameter in assessing the fit of indirect dental restorations. This in vitro study compared the marginal fit of computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated polyetheretherketone (PEEK), graphene-containing, and zirconia crowns. Materials and methods: Forty-five crowns were divided equally into three groups. Group I (PEEK), group II (graphene-containing), and group III (zirconia), with 15 crowns per group. The crowns were cemented onto their corresponding dies, and marginal gaps were evaluated using scanning electron microscopy (SEM) at four locations: mid-buccal, mid-lingual, mid-mesial, and mid-distal. Measurements were recorded in micrometers (µm). One-way ANOVA, followed by Tukey's post hoc test, was used to compare the groups. Statistical significance was set at p < 0.05. Results: Significant differences among the three groups were observed at all four measurement sites (p < 0.001). The PEEK crowns demonstrated the lowest mean marginal gaps at the buccal (25.98 ± 3.10 µm), lingual (25.04 ± 2.64 µm), mesial (25.97 ± 3.01 µm), and distal (24.86 ± 3.22 µm) sites. Zirconia crowns exhibited the highest values at the buccal (48.65 ± 6.02 µm), lingual (46.70 ± 8.87 µm), mesial (45.50 ± 6.77 µm), and distal (43.20 ± 7.53 µm) sites, while graphene-containing crowns showed intermediate values. Post hoc analysis identified significant differences between PEEK and both other materials at all sites (p < 0.001). Differences between graphene-containing and zirconia crowns were significant at the buccal, lingual, and distal sites, but not at the mesial site (p = 0.061). Conclusion: Under the conditions of this in vitro study, PEEK crowns demonstrated smaller marginal gaps than graphene-containing and zirconia crowns. Further investigations incorporating simulated oral aging, mechanical testing, and clinical follow-up are needed to establish the clinical relevance and long-term performance of these materials.

Authors

Publication Details

Journal
Cureus
Published
2026-11-19
DOI
https://doi.org/10.7759/cureus.119936
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Evaluation of the Marginal Fit of Graphene-Based Crowns and Two Other Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM)-Fabricated Crown Materials: An In Vitro Study

Venkata Ratna Kumar Rudravaram, Anuja Singaraju, Deepthi Maya, Kuppala Venkata Sreekanth et al.
Cureus
Dental materials and restorations
article

Comparative Evaluation of the Marginal Fit of Graphene-Based Crowns and Two Other Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM)-Fabricated Crown Materials: An In Vitro Study

Venkata Ratna Kumar Rudravaram, Anuja Singaraju, Deepthi Maya, Kuppala Venkata Sreekanth, Anjuru Sowmya, Bhavana K.V, Santosh Pusuluri
article en

Abstract

Background and objective: Marginal adaptation is an important parameter in assessing the fit of indirect dental restorations. This in vitro study compared the marginal fit of computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated polyetheretherketone (PEEK), graphene-containing, and zirconia crowns. Materials and methods: Forty-five crowns were divided equally into three groups. Group I (PEEK), group II (graphene-containing), and group III (zirconia), with 15 crowns per group. The crowns were cemented onto their corresponding dies, and marginal gaps were evaluated using scanning electron microscopy (SEM) at four locations: mid-buccal, mid-lingual, mid-mesial, and mid-distal. Measurements were recorded in micrometers (µm). One-way ANOVA, followed by Tukey's post hoc test, was used to compare the groups. Statistical significance was set at p < 0.05. Results: Significant differences among the three groups were observed at all four measurement sites (p < 0.001). The PEEK crowns demonstrated the lowest mean marginal gaps at the buccal (25.98 ± 3.10 µm), lingual (25.04 ± 2.64 µm), mesial (25.97 ± 3.01 µm), and distal (24.86 ± 3.22 µm) sites. Zirconia crowns exhibited the highest values at the buccal (48.65 ± 6.02 µm), lingual (46.70 ± 8.87 µm), mesial (45.50 ± 6.77 µm), and distal (43.20 ± 7.53 µm) sites, while graphene-containing crowns showed intermediate values. Post hoc analysis identified significant differences between PEEK and both other materials at all sites (p < 0.001). Differences between graphene-containing and zirconia crowns were significant at the buccal, lingual, and distal sites, but not at the mesial site (p = 0.061). Conclusion: Under the conditions of this in vitro study, PEEK crowns demonstrated smaller marginal gaps than graphene-containing and zirconia crowns. Further investigations incorporating simulated oral aging, mechanical testing, and clinical follow-up are needed to establish the clinical relevance and long-term performance of these materials.

Cureus
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon