Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS

This paper introduces a protection scheme for a grid‐connected wind‐turbine power‐conversion system employing a Permanent Magnet Synchronous Generator (PMSG), a dynamic voltage restorer (DVR), and a battery energy storage system (BESS). The BESS is integrated into the DC‐link through a bidirectional buck‐boost converter (BBBC) to support voltage regulation during wind‐speed fluctuations and grid disturbances. Particle swarm optimization (PSO) is used offline to tune the BBBC PI‐controller parameters, improving DC‐link voltage regulation through BESS charging and discharging. The AC side of the DVR is connected in series with the PMSG terminal, while its DC side is coupled to the DC bus. A three‐level Neutral Point Clamped Multi‐Level Inverter (NPC‐MLI) is employed for the DVR and is activated during voltage sags and swells affecting the terminal voltage. The proposed scheme was evaluated using MATLAB/Simulink under varying wind speeds and different grid‐disturbance conditions. Compared with the two‐level DVR, the three‐level NPC‐based DVR reduced the PMSG terminal‐voltage THD from 0.41%–0.62% to 0.28%–0.54% under the investigated voltage‐sag faults and from 0.36%–0.53% to 0.19%–0.48% under asymmetric and symmetric voltage‐swell conditions. Moreover, compared with the conventional PI controller, the PSO‐tuned PI controller reduced DC‐link voltage overshoot and undershoot under wind‐speed variation, voltage sag, and voltage swell conditions, while providing shorter settling times during voltage sag and swell and maintaining the DC‐link voltage close to its reference throughout the investigated wind‐speed variations. These improvements were demonstrated in MATLAB/Simulink for the investigated parameter set and disturbance scenarios.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2026-11-18
DOI
https://doi.org/10.1002/ese3.70704
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS

Ameer Lateef Saleh, Nabil Mohammed, Ali Kadhim Abdulabbas, László Számel et al.
Energy Science & Engineering
Wind Turbine Control Systems
article

Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS

Ameer Lateef Saleh, Nabil Mohammed, Ali Kadhim Abdulabbas, László Számel, Ahmed Muthanna Nori
article en

Abstract

This paper introduces a protection scheme for a grid‐connected wind‐turbine power‐conversion system employing a Permanent Magnet Synchronous Generator (PMSG), a dynamic voltage restorer (DVR), and a battery energy storage system (BESS). The BESS is integrated into the DC‐link through a bidirectional buck‐boost converter (BBBC) to support voltage regulation during wind‐speed fluctuations and grid disturbances. Particle swarm optimization (PSO) is used offline to tune the BBBC PI‐controller parameters, improving DC‐link voltage regulation through BESS charging and discharging. The AC side of the DVR is connected in series with the PMSG terminal, while its DC side is coupled to the DC bus. A three‐level Neutral Point Clamped Multi‐Level Inverter (NPC‐MLI) is employed for the DVR and is activated during voltage sags and swells affecting the terminal voltage. The proposed scheme was evaluated using MATLAB/Simulink under varying wind speeds and different grid‐disturbance conditions. Compared with the two‐level DVR, the three‐level NPC‐based DVR reduced the PMSG terminal‐voltage THD from 0.41%–0.62% to 0.28%–0.54% under the investigated voltage‐sag faults and from 0.36%–0.53% to 0.19%–0.48% under asymmetric and symmetric voltage‐swell conditions. Moreover, compared with the conventional PI controller, the PSO‐tuned PI controller reduced DC‐link voltage overshoot and undershoot under wind‐speed variation, voltage sag, and voltage swell conditions, while providing shorter settling times during voltage sag and swell and maintaining the DC‐link voltage close to its reference throughout the investigated wind‐speed variations. These improvements were demonstrated in MATLAB/Simulink for the investigated parameter set and disturbance scenarios.

Energy Science & Engineering
University of Basrah (IQ), Budapest University of Technology and Economics (HU), University of Misan (IQ), Imam Ja’afar Al-Sadiq University (IQ)
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon