Dynamic long-axial field-of-view 64Cu-DOTATATE PET/CT demonstrates comparable imaging from 30 to 60 min post-injection in patients with neuroendocrine neoplasms
Background Whole-body PET/CT with radiolabeled somatostatin receptor analogs, e.g. [ 64 Cu]Cu-DOTATATE ( 64 Cu-DOTATATE) is central in managing patients with neuroendocrine neoplasms (NEN). PET/CT is typically performed 1 h post injection (p.i.), while imaging is feasible up to 3 h p.i. Using dynamic long-axial field-of-view (LAFOV) PET, we investigated whether imaging earlier than 1 h p.i. is possible. Methods Between July 2022 and September 2023, 10 patients with biopsy-verified NEN referred for routine 64 Cu-DOTATATE PET/CT were included. Patients underwent dynamic LAFOV PET (vertex to mid-femur) from 0 to 45 min p.i. followed by a 10-minute LAFOV PET with a diagnostic CT at approximately 60 min p.i. Early acquisitions were generated at 5–15 (PET 5-15 ), 15–25 (PET 15-25 ), 25–35 (PET 25-35 ) and 35–45 (PET 35-45) min p.i. Lesion counts by organ and concordant/discordant lesions in the earlier reconstructions were analyzed and compared with the reference at 60–70 (PET 60-70 ) min p.i. Regions of interest were drawn for representative lesions and background regions in blood and liver. Tumor-to-background (TBR) was calculated using liver as background. Results Patients had small intestinal ( n = 6), pancreatic ( n = 3) and lung ( n = 1) primary NEN. All had metastatic disease (358 lesions total). Blood-pool activity declined rapidly and liver uptake reached a plateau at 20 min. Mean TBR (95% CI) at 30 min and 1 h was 4.3 (2.7–5.9) and 4.3 (3.0-5.6), respectively ( p = 0.85). Lesions detected by PET 25−35 and PET 35−45 were concordant with PET 60−70 , while PET 5−15 and PET 15−25 had sensitivity of 94.1% and 98.0%, respectively. Conclusion Dynamic LAFOV 64 Cu-DOTATATE PET/CT enabled the study of optimized acquisition timing. In 10 patients with NEN, PET 25−35 and PET 35−45 visualized all lesions as seen in reference PET 60−70 . Furthermore, TBR at 30 min was similar with 1 h p.i. acquisition. These findings suggest feasibility of image acquisition from approximately 30 min p.i.
Authors
- Esben Andreas Carlsen (ORCID: https://orcid.org/0000-0002-5231-4197)
- Camilla Bardram Johnbeck
- Andreas Kjær (ORCID: https://orcid.org/0000-0002-2706-5547)
- Thomas Lund Andersen (ORCID: https://orcid.org/0000-0002-2860-6317)
- Mathias Loft
Publication Details
- Journal
- EJNMMI Research
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1186/s13550-026-01535-4
- Primary Topic
- Neuroendocrine Tumor Research Advances
- Type
- article
- Field-Weighted Citation Impact
- 0.00