Evaluation of vibration transmissibility and ergonomic usability of anti-vibration gloves at real workstations

Exposure to hand transmitted vibration is common in workplaces using hand held-tools and contributes to upper limb disorders, including hand-arm vibration syndrome. Anti-vibration gloves are often the only personal protective equipment available, but their use remains limited because of discomfort and reduced manual dexterity, so glove assessment should extend beyond laboratory testing to real working conditions. This article proposes an extension of ISO 10819 based on eight vibration transmission coefficients determined in situ, together with comfort-related parameters such as dexterity and the force required to bend the fingers. The method was applied at four workstations differing in vibration characteristics, using an ISO 10819-compliant glove of a new design as a case study. Frequency-weighted exposure was reduced by 10–56% depending on the workstation, although at one workstation the results indicated amplification in one of the analysed axes. Compliance with ISO 10819 therefore does not guarantee protection at every workstation.

Authors

Institutions

Publication Details

Journal
Ergonomics
Published
2026-11-19
DOI
https://doi.org/10.1080/00140139.2026.2761483
Primary Topic
Effects of Vibration on Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of vibration transmissibility and ergonomic usability of anti-vibration gloves at real workstations

Jacek Zając, Piotr Kowalski, Adrian Alikowski, Julia Idczak
Ergonomics
Effects of Vibration on Health
article

Evaluation of vibration transmissibility and ergonomic usability of anti-vibration gloves at real workstations

Jacek Zając, Piotr Kowalski, Adrian Alikowski, Julia Idczak
article en

Abstract

Exposure to hand transmitted vibration is common in workplaces using hand held-tools and contributes to upper limb disorders, including hand-arm vibration syndrome. Anti-vibration gloves are often the only personal protective equipment available, but their use remains limited because of discomfort and reduced manual dexterity, so glove assessment should extend beyond laboratory testing to real working conditions. This article proposes an extension of ISO 10819 based on eight vibration transmission coefficients determined in situ, together with comfort-related parameters such as dexterity and the force required to bend the fingers. The method was applied at four workstations differing in vibration characteristics, using an ISO 10819-compliant glove of a new design as a case study. Frequency-weighted exposure was reduced by 10–56% depending on the workstation, although at one workstation the results indicated amplification in one of the analysed axes. Compliance with ISO 10819 therefore does not guarantee protection at every workstation.

Ergonomics
Central Institute for Labour Protection (PL)
Effects of Vibration on Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon